[Federal Register Volume 77, Number 178 (Thursday, September 13, 2012)]
[Rules and Regulations]
[Pages 56718-56735]
From the Federal Register Online via the Government Publishing Office [www.gpo.gov]
[FR Doc No: 2012-22253]
[[Page 56717]]
Vol. 77
Thursday,
No. 178
September 13, 2012
Part II
Department of Health and Human Services
-----------------------------------------------------------------------
42 CFR Part 37
Specifications for Medical Examinations of Underground Coal Miners;
Final Rule
Federal Register / Vol. 77 , No. 178 / Thursday, September 13, 2012 /
Rules and Regulations
[[Page 56718]]
-----------------------------------------------------------------------
DEPARTMENT OF HEALTH AND HUMAN SERVICES
42 CFR Part 37
[Docket No. CDC-2011-0013; NIOSH-225]
RIN 0920-AA21
Specifications for Medical Examinations of Underground Coal
Miners
AGENCY: Centers for Disease Control and Prevention (CDC), Department of
Health and Human Services (HHS).
ACTION: Final rule.
-----------------------------------------------------------------------
SUMMARY: This final rule modifies the Department of Health and Human
Services (HHS) regulations for medical examinations of underground coal
miners. Existing regulations established specifications for providing,
interpreting, classifying, and submitting film-based roentgenograms
(now commonly called chest radiographs or X-rays) of underground coal
miners. The revised standards modify the requirements to permit the use
of film-based radiography systems and add a parallel set of standards
permitting the use of digital radiography systems. An additional
amendment requires coal mine operators to provide the National
Institute for Occupational Safety and Health (NIOSH) with employee
rosters to assist the Coal Workers' Health Surveillance Program in
improving participation by miners.
DATES: This final rule is effective October 15, 2012. The incorporation
by reference of certain publications listed in the rule is approved by
the Director of the Federal Register as of October 15, 2012.
FOR FURTHER INFORMATION CONTACT: Anita Wolfe, Public Health Analyst,
Division of Respiratory Disease Studies, National Institute for
Occupational Safety and Health, 1095 Willowdale Road, MS B208,
Morgantown, WV 26505, Telephone (888) 480-4042 (this is a toll-free
number). Information requests can also be submitted by email to
[email protected].
SUPPLEMENTARY INFORMATION: The preamble to this notice of final
rulemaking is organized as follows:
Table of Contents
I. Public Participation
II. Background
A. Scope of Rulemaking
B. Impact of Rulemaking
III. Summary of Final Rule and Response to Public Comments
A. Subpart--Chest Radiographic Examinations
B. Subpart--Autopsies
IV. Regulatory Assessment Requirements
A. Executive Orders 12866 and 13563
B. Regulatory Flexibility Act
C. Paperwork Reduction Act
D. Small Business Regulatory Enforcement Fairness Act
E. Unfunded Mandates Reform Act of 1995
F. Executive Order 12988 (Civil Justice)
G. Executive Order 13132 (Federalism)
H. Executive Order 13045 (Protection of Children From
Environmental Health Risks and Safety Risks)
I. Executive Order 13211 (Actions Concerning Regulations That
Significantly Affect Energy Supply, Distribution, or Use)
J. Plain Writing Act of 2010
V. Final Rule
I. Public Participation
HHS received comments from 11 individuals and organizations. Four
of the commenters are B Readers; two are West Virginia physicians; one
is a private citizen; and one is a U.S. Senator. Comments were also
submitted on behalf of the National Council on Radiation Protection and
Measurements (NCRP), the American Society of Radiologic Technologists,
and a law firm representing two coal companies and the West Virginia
Coal Workers' Pneumoconiosis Fund.
II. Background
All mining work generates fine particles of dust in the air. Coal
miners who inhale excessive dust are known to develop a group of
diseases of the lungs and airways, including chronic bronchitis,
emphysema, chronic obstructive pulmonary disease, silicosis, and coal
workers' pneumoconiosis (CWP).\1\ To address such threats to the U.S.
coal mining workforce, the Coal Mine Health and Safety Act was enacted
in 1969 (Pub. L. 91-173) and amended by the Federal Mine Safety and
Health Act of 1977 (Pub. L. 95-164, 30 U.S.C. 801 et seq.) (Mine Act).
The statutes included an enforceable 2 milligrams per cubic meter limit
on respirable dust exposure during underground coal mine work (30
U.S.C. 842(b)(2)). The science available at that time indicated that
enforcement of this limit would greatly reduce the development of CWP,
but could not ensure that all miners would be protected from developing
disabling or lethal disease.
---------------------------------------------------------------------------
\1\ Petsonk EL, Parker JE [2008]. Coal workers' lung diseases
and silicosis. In: Fishman AP, Elias J, Fishman J, Grippi M, Senior
R, Pack A eds. Fishman's Pulmonary Diseases and Disorders. 4th ed.
New York: McGraw-Hill, pp. 967-980.
---------------------------------------------------------------------------
The NIOSH Coal Workers' Health Surveillance Program (CWHSP), also
mandated by the Mine Act, was developed to detect CWP and prevent
progression in individual miners, while at the same time providing
information for evaluation of temporal and geographic trends in
pneumoconiosis. The Mine Act grants NIOSH general authority to issue
regulations as the Institute deems appropriate in carrying out
provisions of the Act and specifically directs that medical
examinations for underground coal miners shall be given in accordance
with specifications prescribed by NIOSH (30 U.S.C. 843(a), 957).
To inform each miner of his or her health status, the Act requires
that underground coal mine operators offer new workers a chest
roentgenogram (hereafter chest radiograph or X-ray) through an approved
facility as soon as possible after employment starts. Three years later
a miner must be offered a second chest radiograph. If this second
examination reveals evidence of pneumoconiosis, the miner is entitled
to a third chest radiograph 2 years after the second. Further, all
miners working in an underground coal mine must be offered a chest
radiograph approximately every 5 years. All chest radiographs are to be
given in accordance with specifications prescribed by the Secretary of
Health and Human Services (30 U.S.C. 843(a)).
Chest radiographs taken for the CWHSP are assessed by qualified and
licensed physicians who are A or B Readers. A Readers are physicians
who interpret chest radiographs for clinical purposes. They will have
demonstrated knowledge of the International Labour Office (ILO)
Classification of Radiographs of Pneumoconioses by completing a NIOSH-
approved course or submitting six radiographs with satisfactory
classifications, as specified in 42 CFR 37.51. B Readers are physicians
who have demonstrated proficiency in the use of the ILO classification
system by taking and passing a specially-designed proficiency
examination offered by NIOSH, as specified in 42 CFR 37.51.
HHS proposed amendments to the existing part 37 regulations in a
document published in January, 2012 (77 FR 1360, January 9, 2012).
A. Scope of Rulemaking
Existing regulations under 42 CFR part 37 provide rules and
specifications for giving, interpreting, classifying, and submitting
chest radiographs as required under section 203 of the Federal Mine
Safety and Health Act of 1977, as amended (30 U.S.C. 843). Those rules
will remain in effect. This rulemaking does not substantially alter the
current standards.
Significantly, the new rule expands the availability of chest
radiographic examinations by establishing additional
[[Page 56719]]
options for giving, interpreting, classifying, and submitting
digitally-acquired radiographs under the same scope as the existing
rule does for film radiographs. The final rule establishes the minimum
specifications for methods, procedures, quality assurance,
documentation, and equipment including computer software for facilities
seeking approval to perform and submit digital radiographic
examinations as well as the physician readers who interpret, classify,
and submit reports using those radiographs. The final rule also makes
limited changes to general requirements to reflect current terminology
(such as the use of ``radiograph'' instead of ``roentgenogram'' which
is no longer commonly used), practice or needs, such as requiring mine
operators to provide a roster of current miners to NIOSH, which uses
this information to promote miner participation in the Coal Workers'
Health Surveillance Program. The final rule does not modify existing
requirements for miner radiographic examinations, eligibility, or other
rights, including transfer of affected miners in accordance with 30 CFR
part 90.
B. Impact of Rulemaking
The U.S. Department of Labor (DOL) will likely amend its Black Lung
Benefits Act (BLBA) program regulations to correspond with this final
rule. The BLBA provides disability compensation and medical benefits to
miners disabled by pneumoconiosis and monthly compensation to their
eligible survivors (30 U.S.C. 901-944). Because DOL is required to
consult with NIOSH on the development of criteria for medical tests for
coal miners (30 U.S.C. 902(f)(1)(D)), DOL has modeled its technical
requirements for chest radiographs on those adopted by NIOSH for the
Coal Workers' Health Surveillance Program (see 20 CFR 718.102 and 20
CFR part 718 Appendix A). DOL's Occupational Safety and Health
Administration (OSHA) might enable the use of digital chest images for
medical surveillance under its asbestos regulations for general
industry, shipyard employment, and construction (29 CFR 1910.1001
Appendix E, 29 CFR 1915.1001 Appendix E, and 29 CFR 1926.1101 Appendix
E, respectively). OSHA's asbestos regulations include requirements for
screening asbestos-exposed individuals using chest radiography.
Enabling the use of modern digital chest imaging in that setting will
involve similar technical considerations as are addressed in this final
rule. However, OSHA's asbestos regulations are not linked by statute or
regulation to this final rule.
The DOL standards refer to chest ``roentgenograms,'' an outdated
term which NIOSH is replacing with the more contemporary
``radiograph.'' The DOL standards also rely upon the same ILO standards
for the classification of radiographs, and might need to be amended to
comport with the 2011 version of the ILO Classification, as referenced
in this final rule. Finally, the DOL standards refer to film-based
images and might need to be expanded to refer to digitally-acquired
images in order to allow for such images to be used for purposes of
determining eligibility for compensation.
III. Summary of Final Rule and Response to Public Comments
This final rule establishes new requirements for digital
radiography under existing part 37 of 42 CFR--Specifications for
Medical Examinations of Underground Coal Miners. The new provisions
supplement and update the existing requirements for film-screen
radiographs by establishing standards for digital radiographs. The
following is a section-by-section introduction to each rule section,
including a summary of the public comments and NIOSH responses to them.
In general, the commenters are supportive of this rulemaking and
welcome its implementation. Commenters offered thoughtful and practical
suggestions for improvement of the final rule text, and HHS has adopted
many of those suggestions.
Table 1 matches the current regulatory provisions with the
corresponding final provisions. The final regulatory text is provided
in the last section of this notice.
Table 1--Current and Final Provisions
------------------------------------------------------------------------
Current regulation Final regulation
------------------------------------------------------------------------
37.2 Definitions....................... 37.2 Definitions.
37.3 Chest roentgenograms required for 37.3 Chest radiographs required
miners. for miners.
37.4 Plans for chest roentgenographic 37.4 Plans for chest
examinations. radiographic examinations.
37.5 Approval of plans................. 37.5 Approval of plans.
37.6 Chest roentgenographic 37.6 Chest radiographic
examinations conducted by the examinations conducted by the
Secretary. Secretary.
37.7 Transfer of affected miner to less 37.7 Transfer of affected miner
dusty area. to less dusty area.
37.8 Roentgenographic examination at 37.8 Radiographic examination
miner's expense. at miner's expense.
37.10 Standards incorporated by
reference.
37.20 Miner identification document.... 37.20 Miner identification
document.
37.40 General provisions............... 37.40 General provisions.
37.41 Chest roentgenogram 37.41 Chest radiograph
specifications. specifications--film.
37.42 Approval of roentgenographic 37.42 Chest radiograph
facilities. specifications--digital
radiography systems.
37.43 Protection against radiation 37.43 Approval of radiographic
emitted by Roentgenographic equipment. facilities that use film.
37.44 Approval of radiographic
facilities that use digital
radiography systems.
37.45 Protection against
radiation emitted by
radiographic equipment.
37.50 Interpreting and classifying 37.50 Interpreting and
chest roentgenogram. classifying chest radiographs--
film.
37.51 Proficiency in the use of systems 37.51 Interpreting and
for classifying the pneumoconioses. classifying chest radiographs--
digital radiography systems.
37.52 Method of obtaining definitive 37.52 Proficiency in the use of
interpretations. systems for classifying the
pneumoconioses.
37.53 Notification of abnormal 37.53 Method of obtaining
roentgeno graphic findings. definitive interpretations.
37.54 Notification of abnormal
radiographic findings.
37.60 Submitting required chest 37.60 Submitting required chest
roentgenograms and miner radiographs and miner
identification documents. identification documents.
37.70 Review of interpretations........ 37.70 Review of
interpretations.
37.80 Availability of records.......... 37.80 Availability of records.
37.200 Scope........................... 37.200 Scope.
[[Page 56720]]
37.201 Definitions..................... 37.201 Definitions.
37.202 Payment for autopsy............. 37.202 Payment for autopsy.
37.203 Autopsy specifications.......... 37.203 Autopsy specifications.
37.204 Procedure for obtaining payment. 37.204 Procedure for obtaining
payment.
------------------------------------------------------------------------
Section 37.1 Scope
This existing section provides the scope of these provisions, and
remains unchanged from the current regulation. HHS received no comments
on this section.
Section 37.2 Definitions
HHS amends a number of terms in the existing Sec. 37.2 to reflect
updated terminology and references.
Comment: One commenter supports and agrees with the definition of
``radiologic technologist'' included in Section 37.2 but suggests that
the definition contained in this section be amended to require the
individual to have ``completed a formal training program in radiography
leading to a certificate, an associate degree, or a bachelor's degree
and participated in the voluntary initial certification and annual
renewal of registration for radiologic technologists in radiography
offered by the American Registry of Radiologic Technologists.'' The
definition proposed by HHS would make those credentials ``optimal,''
but not required.
HHS response: HHS considers the described training, certification,
and ongoing renewals as optimum for radiologic technologists. However,
because State and Territorial governments have regulatory authority for
oversight of radiologic technologists, the Federal government cannot
require such credentials. Accordingly, the commenter's suggestion
cannot be implemented.
Section 37.3 Chest Radiographs Required for Miners
This existing section requires mine operators to provide miners an
opportunity to receive a chest radiograph. HHS amends this provision to
delete and replace outdated text. HHS received no comments on Sec.
37.3.
Section 37.4 Plans for Chest Radiographic Examinations
This existing section requires that mine operators submit to NIOSH
a Coal Mine Operator's Plan (Form CDC/NIOSH (M)2.10, OMB 0920-0020,
exp. June 30, 2014) for chest radiographic examinations, including the
beginning and ending dates of the 6-month period for voluntary
examinations, and the name and location of the approved X-ray facility
or facilities. HHS received no comments on Sec. 37.4.
Section 37.5 Approval of Plans
This existing section outlines the process undertaken by the
Secretary of HHS to approve or deny approval of a Coal Mine Operator's
Plan (Form CDC/NIOSH (M)2.10, OMB 0920-0020, exp. June 30, 2014). HHS
amends this section to redact outdated text and to correct gender-
exclusive language. HHS received no comments on Sec. 37.5.
Section 37.6 Chest Radiographic Examinations Conducted by the Secretary
This existing section details the conditions under which the HHS
Secretary will determine whether to conduct a chest radiographic
examination. HHS amends this section to replace outdated text with
current terminology. HHS received no comments on Sec. 37.6.
Section 37.7 Transfer of Affected Miner to Less Dusty Area
Under 30 CFR part 90, miners whose radiographs show specific
categories of pneumoconiosis are offered the right to frequent
workplace dust monitoring, and transfer to another position in an area
of the mine where the concentration of respirable dust in the mine
atmosphere is in compliance with MSHA requirements in 30 CFR 90.3. HHS
received no comments on Sec. 37.7.
Section 37.8 Radiographic Examination at Miner's Expense
This existing section provides for any miner who wishes to obtain a
radiographic examination at his or her own expense. HHS received no
comments on Sec. 37.8.
Section 37.10 Standards Incorporated by Reference
HHS has added Sec. 37.10 to consolidate all of the standards
incorporated by reference in Part 37. There are no substantive changes
to the referenced standards.
Section 37.20 Miner Identification Document
This existing section requires the completion of a Miner
Identification Document (Form CDC/NIOSH (M)2.9, OMB 0920-0020, exp.
June 30, 2014) for each miner when the chest radiograph is made. HHS
received no comments on Sec. 37.20.
Section 37.40 General Provisions
This existing section outlines general provisions for chest
radiographic examinations. HHS received no comments on Sec. 37.40.
However, paragraph (c) is edited to indicate that a radiograph may also
be performed by a radiologic technologist to comport with the
requirements in Sec. Sec. 37.41 and 37.42.
Section 37.41 Chest Radiograph Specifications--Film
This existing section establishes performance standards for the
acquisition of chest radiographs using film-screen technology. HHS
amends this section to update terminology and standards. In response to
comments, discussed below, subsection (c) is amended to require that
chest radiographs be performed by either a physician or a person
working under the supervision of a physician, or by a radiologic
technologist. Subsection (d) is amended in response to a comment to
Sec. 31.42, below, to specify that the size of the focal spot should
be described as the measured size and not the nominal size. Subsection
(n) is also amended in response to comments (see below) to require that
each radiograph be marked with the miner's date of birth, in addition
to the identification of the facility where it was made, the miner's
Social Security number, and the date on which the X-ray was made.
Comment: One commenter supports the change to subsection (c),
requiring that a radiologic technologist perform chest radiography
using film. According to the commenter, a registered radiologic
technologist in radiography is educationally prepared and clinically
competent to perform chest radiography. Several commenters do not
approve of the proposed requirement, asserting that when radiographs of
miners under this regulation are taken
[[Page 56721]]
by State approved and licensed radiology facilities in a physician's
office or clinic and that X-ray is performed under the direct
supervision of a facility medical or osteopathic physician, it is not
necessary to employ a radiology technician. Commenters state that
allowing other trained professionals to make radiographs will improve
the availability of surveillance health examination in mining regions.
HHS response: The intent of the wording in this section is to
assure that coal miners are provided high quality radiographic
examinations using professionally-accepted methods that minimize
radiation exposure. In order to optimize quality, safety, and
accessibility goals, the wording of Sec. 37.41(c) has been edited to
indicate that the X-ray may be made either a physician or a person
working under the supervision of a physician, or by a radiologic
technologist.
Comment: One commenter states that use of Social Security number as
an identifier is increasingly difficult. The individual suggests that
for examinations under this regulation, the image file or DICOM header
include the date of birth of the individual whose chest is imaged.
HHS response: HHS concurs and has accordingly modified the
regulatory text in Sec. 37.41(n) to require that the X-ray also be
marked with the miner's date of birth.
Section 37.42 Chest Radiograph Specifications--Digital Radiography
Systems
This new section establishes performance standards for the
acquisition of chest radiographs using digital radiography systems,
including digital radiography and computed radiography. Section
37.42(b), (c), (d), and (i)(4) is amended in response to comments, as
discussed below. Section 37.42(i)(5)(i)(A) is amended to include DICOM
Standard PS 3.3-2001, Annex A, Computed Radiography Image Information
Object Definition. This section title was inadvertently omitted, and
references an image information object which was already a required
component of older CR equipment models.
Comment: One commenter notes that the regulations ``do not require
certification that the individual digital image taken both complied
with the specifications of 42 CFR 37.42 and that the facility where the
digital image was taken has been approved, and that its approval was
current under 42 CFR 37.44, when the digital image was taken.'' The
comment suggests either the recording form be revised or alternatively,
a web-based listing of NIOSH-approved radiographic facilities be made
available.
HHS response: CWHSP will continue to maintain a web-based listing
of radiographic facilities that are NIOSH-approved under 42 CFR part
37, including directions and maps to locate approved facilities. (See,
http://www.cdc.gov/niosh.)
Comment: One commenter indicates that the size of the detector
specified in Sec. 37.42(b) would exclude one prominent equipment
provider, and also would unnecessarily prohibit use of larger
detectors. The commenter further suggests that the specification of a 5
megapixel matrix size be eliminated since the requirements for pixel
pitch and detector size are sufficient, and these are not entirely
consistent with the specified matrix size. The commenter further
expresses concern that the requirement that ``Spatial resolution shall
be at least 2.4 line pair per millimeter'' is not adequately defined.
The commenter offers several methods to clarify the requirement,
including the suggestion that the modulation transfer function be
included in the system performance requirements in Sec. 37.42(i)(4).
HHS response: In response to this comment, the text of the final
rule is modified to specify only pixel pitch and detector size, without
a specific matrix size. Specifically, HHS has omitted the proposed
maximum size for image detectors. The final rule text now specifies a
minimum area and width for detectors which will accommodate the
equipment mentioned in the comment (Sec. 37.42(b)). Per the
commenter's suggestion, Sec. 37.42(i)(4) is also amended to address
the modulation transfer function (MTF). However, HHS reminds
stakeholders that under Sec. 37.42(i)(6), NIOSH retains the discretion
to evaluate image quality by requiring the facility to include a test
object on each X-ray.
Comment: One commenter states that when radiographs of miners under
this regulation are taken by State-approved and licensed radiology
facilities in a physician's office or clinic and that X-ray is
performed under the direct supervision of a facility medical or
osteopathic physician, it is not necessary to employ a radiologic
technologist (Sec. 37.42(c)).
HHS Response: In order to optimize quality, safety, and
accessibility goals, the wording of Sec. 37.42(c) has been edited to
indicate that the X-ray may be made by either a physician or a person
working under the supervision of a physician, or by a radiologic
technologist.
Comment: A commenter suggests that, in relation to the
specifications for X-ray generators in 37.42(d), the size of the focal
spot should be described as the measured size and not the nominal size.
HHS response: HHS has amended the final rule text to specify the
measured, rather than nominal width of the focal point. A similar
change is made to Sec. 37.41(d), specifications for film radiographs.
Comment: One commenter suggests that the application of edge
enhancement techniques in image processing may result in inaccurate
appearances and emphasizes the importance of using full uncompressed
DICOM image files, and requiring medical grade monitors (Sec.
37.42(i)).
HHS response: HHS concurs with the commenter and believes that the
provisions in Sec. 37.42(i) appropriately restrict use of edge
enhancement techniques, require compression of DICOM image files to be
fully reversible (lossless), and stipulate that the image display
devices must meet the Grayscale Standard Display Function for
diagnostic monitors specified in DICOM Part 14.
Comment: One commenter recommends that Sec. 37.42(i)(5)(ii)(A) be
amended to require that the image file or DICOM header include the date
of birth of the individual whose chest is imaged. Another commenter
indicates that determining whether imaging parameters have been met
will be difficult because only basic information is contained in the
DICOM header, thus placing a burden on small hospitals attempting to
comply with quality assurance standards.
HHS response: HHS concurs that the miner's date of birth should be
required for film radiographs. For digital radiographs, unique
identification of each miner, chest image, facility, and date and time
of the examination are encoded within the image information object
according to Part 3 (PS 3.3-2009) of the DICOM standard, as specified
in Sec. 37.42. Accordingly, HHS has not amended the text of Sec.
37.42(i)(5)(ii)(A).
With regard to the quality assurance standards, since the inception
of the Program, there has been a continuing concern for both safety and
image properties, and quality assurance has always been a component of
the 42 CFR Part 37 specifications. In this final rule, this
professionally recommended and prudent element is being extended to
cover the newly permitted digital imaging systems.
Comment: A commenter expresses concern that images will be rejected
and deleted even if, due to emergency situations, patients may be
elderly, too
[[Page 56722]]
ill for a high quality standard PA image, etc. The commenter further
states that all images have useful information, and that no images
should be discarded (Sec. 37.42(i)(11)).
HHS response: The rule allows each physician reader to maintain his
or her individual professional judgment in determining the quality of
an image that is to be classified. The rule does not specifically
require deletion of image files, but requires that when an image is
deemed suboptimal and imaging is immediately repeated to obtain a
better quality image, the original suboptimal file be fully deleted or
rendered permanently inaccessible. The requirement to delete image
files after they are transferred to NIOSH or if found substandard and
thus immediately repeated is entirely analogous to the current rules
regarding destruction of copies of film radiographs, and is only
intended to assure maintenance of worker confidentiality for
participants in the mandated Program. Approved facilities are permitted
to forward to NIOSH all files of chest radiographic examinations that
they have performed for any eligible coal miner, independent of image
quality.
Section 37.43 Approval of Radiographic Facilities That Use Film
Section 37.43 comprises the current requirements in existing Sec.
37.42--Approval of roentgenographic facilities. HHS received no
comments on Sec. 37.43.
Section 37.44 Approval of Radiographic Facilities That Use Digital
Radiography Systems
Section 37.44 establishes standards for the approval of
radiographic facilities that use digital radiography systems. These
standards mirror those for film-screen technology.
Comment: A commenter states that it is the position of the American
Society of Radiologic Technologists that radiographic technique charts
be used by persons performing radiography and that all health care
facilities make radiographic technique charts available to persons
performing radiography. The commenter is pleased to see this position
reflected by the inclusion of the provision in Sec. 37.44(g)(2) along
with the requirement that facilities have in place a documented quality
assurance program.
HHS response: HHS appreciates this comment.
Section 37.45 Protection Against Radiation Emitted by Radiographic
Equipment
This provision requires that radiographic equipment conform to
applicable State, territorial, and Federal regulations. Where no State,
Territorial or Federal regulations apply, the section incorporates by
reference the recommendations of the National Council on Radiation
Protection and Measurements (NCRP).
Comment: A commenter representing the NCRP provided updated
references to the publications of his organization for the text of the
regulation.
HHS response: HHS appreciates the comment and has amended the final
rule text accordingly.
Section 37.50 Interpreting and Classifying Chest Radiographs--Film
Procedures for classifying radiographs are unchanged from the
existing Sec. 37.50, but for updating the requirement that images be
interpreted and classified in accordance with the Guidelines for the
Use of the ILO International Classification of Radiographs for
Pneumoconioses, 2011 edition.\2\ HHS received no comments on Sec.
37.50. HHS is changing the rule text in Sec. 37.50(a) and (c) to
clarify that the Guidelines are being incorporated by reference.
---------------------------------------------------------------------------
\2\ International Labour Office [2011]. Guidelines for the use
of ILO International Classification of Pneumoconiosis, revised
edition 2011). Geneva, Switzerland: International Labour
Organization. Occupational Safety and Health Series No. 22 (Rev.
2011).
---------------------------------------------------------------------------
Section 37.51 Interpreting and Classifying Chest Radiographs--Digital
Radiography Systems
Section 37.51 establishes requirements for the classification of
radiographs. Of note, the ILO has recently authorized the use of the
ILO Classification for digital images and authorized a set of standard
digital image files for use during classification. HHS is changing the
rule text in Sec. 37.51(b) and (c) to clarify that the Guidelines are
being incorporated by reference.
Comment: A commenter observes that it can be difficult for a reader
to load the subject images on his or her picture archiving and
communication (PACS) system, due to software issues from the system
manufacturers. The commenter further states that that software in most
PACS systems does not permit viewing of the miner radiograph side-by-
side with another image folder, such as the ILO standard images.
HHS response: NIOSH is aware of this concern, and has applied
considerable resources and effort to make available a specific software
package (NIOSH BViewer[supreg]) which is designed to address this issue
(the BViewer software is available for free download at http://www.cdc.gov/niosh/topics/chestradiography/digital-images.html).
Although initially it is anticipated that some readers may have
difficulty in displaying the standard ILO images along with the miner
radiograph, over time, NIOSH believes that PACS manufacturers will
incorporate software with functionality similar to B Viewer to further
ameliorate this concern.
Section 37.52 Proficiency in the Use of Systems for Classifying the
Pneumoconioses
This section establishes the A and B Reader approval programs, and
is modified from existing Sec. 37.51 to make clarifications in the
current requirements and update older terminology. HHS received no
comments on Sec. 37.52.
Section 37.53 Method of Obtaining Definitive Interpretations
Section 37.53 maintains the standards in existing Sec. 37.52,
which establishes that radiographs will be independently interpreted by
an A Reader and B Reader, or two B Readers, whose classifications must
be in agreement as defined in Sec. 37.53(b); if sufficient agreement
is lacking, NIOSH will obtain a third interpretation.
Comment: One commenter indicates that if the B Reader feels the
image is satisfactory for identifying the abnormality, then it should
not be disqualified if quality assurance standards have not been met.
The commenter feels technical issues should not be used to disqualify
evidence and therefore deny benefits if the individual is not able to
return for repeat testing, and suggests that consensus among 2 or more
B Readers be required where the quality of an image is in dispute.
HHS response: A digital or screen film radiograph will not be
disqualified for technical reasons if two or more B Readers do not find
it unreadable and are able to classify it. The B Reader rates the
quality of the image and classifies it for the presence and severity of
findings associated with pneumoconiosis, but does not assess whether
the facility making the image complied with the quality assurance
specifications in Part 37. The rule does not constrain the reader in
determining whether the image is either satisfactory or unreadable due
to quality issues. Thus, responding to this comment does not
necessitate a change to the rule text.
[[Page 56723]]
Section 37.54 Notification of Abnormal Radiographic Findings
Section 37.54, redesignated from Sec. 37.53, would be revised to
update outdated terminology. The provision would also allow the first
reader to communicate certain information directly to the miner,
including abnormal findings other than pneumoconiosis. As discussed
below, Sec. 37.54(b) is amended in response to public comment.
Comment: One commenter believes that the side-by-side review
referenced in Sec. 37.54(b) can be confusing to the miner, and that
all information regarding X-ray results should be communicated at one
time. The commenter suggests that because the evaluation of findings
other than pneumoconiosis does not require a B Reader, this section
should permit the comparisons to be done by any licensed physician,
and/or that the miner be provided with copies of the relevant images so
that their personal physician can perform the comparison. Finally, the
commenter suggests that communication about health issues be to the
miner, and not the designated physician to reduce the chance of failure
of important communications. Another commenter recommends that NIOSH
utilize available in-house medical expertise to complete the ``side-by-
side'' readings. Outside consultation could still be obtained, where
deemed useful or necessary.
HHS response: HHS agrees with commenters that the use of a B Reader
to interpret findings other than pneumoconiosis is unnecessary. In
response to these comments, HHS has amended Sec. 37.54(b) to indicate
that, instead of a B Reader, NIOSH will arrange for a licensed
physician to compare the most recent image and interpretation to older
ones and inform the miner of any significant changes or progression of
disease or other comments. The rule text is also changed to clarify
that the Department means to refer to abnormal findings other than
pneumoconiosis and substitutes the phrase ``abnormality of cardiac
shape or size'' for ``enlarged heart.''
Section 37.60 Submitting Required Chest Radiographs and Miner
Identification Documents
Section 37.60 is essentially unchanged from existing Sec. 37.60,
which establishes the protocol for submitting radiographs. HHS received
no comments on Sec. 37.60.
Section 37.70 Review of Interpretations
This section is amended only to update terminology. HHS received no
comments on Sec. 37.70.
Section 37.80 Availability of Records for Radiographs
Section 37.80 remains unchanged from the existing requirement,
although terminology in this section is updated. HHS received no
comments on Sec. 37.80.
Section 37.200 Scope
Section 37.200 remains unchanged from the existing explanation that
provisions in this subpart establish conditions under which
pathologists will be paid to conduct autopsies on deceased miners. HHS
received no comments on Sec. 37.200.
Section 37.201 Definitions
Section 37.201 retains the existing definitions for Secretary,
miner, and pathologist, but updates ``ALFORD,'' in the existing
provision to ``NIOSH.'' HHS received no comments on Sec. 37.201.
Section 37.202 Payment for Autopsy
Section 37.202 retains the existing provision setting forth
circumstances under which a pathologist may be paid by the Secretary
for performing an autopsy. HHS received no comments on Sec. 37.202.
Section 37.203 Autopsy Specifications
Section 37.203 retains the existing standards establishing the
manner in which autopsies are conducted. HHS received no comments on
Sec. 37.203.
Section 37.204 Procedure for Obtaining Payment
Section 37.204 retains the existing procedure for submitting a
claim for payment to NIOSH (``NIOSH'' replaces ``ALFORD'' in the rule
text). HHS has received no comments on Sec. 37.204.
IV. Regulatory Assessment Requirements
A. Executive Order 12866 and Executive Order 13563
Executive Orders 12866 and 13563 direct agencies to assess all
costs and benefits of available regulatory alternatives and, if
regulation is necessary, to select regulatory approaches that maximize
net benefits (including potential economic, environmental, public
health and safety effects, distributive impacts, and equity). E.O.
13563 emphasizes the importance of quantifying both costs and benefits,
of reducing costs, of harmonizing rules, and of promoting flexibility.
This final rule is being treated as a ``significant'' action under
E.O. 12866. It provides for the use of digital radiography systems in
the Coal Workers' Health Surveillance Program (CWHSP) administered by
NIOSH under 42 CFR part 37, in cooperation with coal mine operators, to
monitor and protect the health of U.S. coal miners, particularly for
the prevention of coal workers' pneumoconiosis. The current regulations
at 42 CFR part 37 only allow for the use of film-screen radiography
systems in this program. The addition of digital X-ray standards in
part 37 does not require mine operators to change their plans to
accommodate digital radiographs, but it is expected to substantially
increase the amount of access miners will have to radiograph facilities
because the use of film-screen radiography is declining markedly
throughout the United States and specifically in areas where coal
mining is located and where coal miners live. In fact, many clinics
participating in the Program have indicated that they are maintaining
their outdated X-ray film capabilities only because of Program
requirements, and that they intend to switch to digital radiography
when NIOSH allows its use by promulgating this final rule. In general,
most health care facilities have abandoned the use of film-based X-
rays. Mammography was the last mainstream radiology procedure that
required use of film; many facilities made the final switch to digital
several years ago when digital mammography systems became available.
Increased access to radiograph facilities that offer digital X-rays
is expected to result in cost savings to coal miners because they will
not have to drive as far to visit an approved clinic.
Digital radiographs are more cost-effective than their film-based
counterparts because they do not require costly chemical processing,
they eliminate the need for a separate device to develop the image, and
they avoid costs associated with managing and archiving hard-copy
images. Over the past 5 years approximately 100 clinics have submitted
film-screen radiographs to CWHSP. NIOSH queried several clinics on the
costs associated with film-screen radiography, including equipment
maintenance, chemicals, film, and processing. Based on the responses,
it is estimated that the cost to facilities of maintaining film X-ray
technology to provide radiographs for approximately 2,500 coal miners
is between $7,000 and $15,000 per clinic per year. Because NIOSH
expects that most facilities participating in the Program will switch
entirely to digital radiography when this rule is
[[Page 56724]]
promulgated, we estimate a first year cost savings to facilities that
currently provide both film and digital radiographs of between $700,000
and $1,500,000 after they have discontinued the use of film
radiographs.
Although this rule does not require any facility to upgrade to
digital technology, facilities that choose to do so will necessarily
incur costs associated with its acquisition. HHS invited public comment
on these estimates and received one comment asserting that meeting the
rule's quality assurance standards will be prohibitively expensive for
small facilities. As discussed here, HHS expects that facilities
voluntarily upgrading to digital technology will necessarily incur
costs associated with acquiring the technology and meeting regulatory
standards. However, the quality assurance standards in this rule
reflect standard industry practice and should not create burdens for
small facilities already using, or planning to use, digital chest
imaging and wishing to join the CWHSP.
Furthermore, the final rule does not require any radiography
facility to perform digital radiographs for this NIOSH program.
Facilities may continue to perform film-screen radiography under the
current requirements of Part 37 applicable to film-screen radiography,
which would not be substantially changed by this final rule.
The provisions for using the DICOM standard and incorporating by
reference standard best practices for digital radiography used in lung
imaging ensure that the final requirements reflect standard practice
and technology. For these reasons, the rule provisions allowing for the
use of digital radiography and specifying equipment and practice
parameters would not impose any additional costs on coal mine operators
who provide for their miners' participation in this program nor on the
radiography facilities that serve the participating coal miners.
The final rule establishes a new requirement for coal mine
operators to provide to NIOSH a roster of current miners under Sec.
37.4(a)(3). The provision of this roster to NIOSH is current practice
by almost all of the approximately 500 U.S. underground coal mine
operators; therefore codifying this practice in regulation will not
result in any additional cost to mine operators. For these reasons, the
final rule is not considered economically significant, as defined in
sec. 3(f)(1) of E.O. 12866.
The rule is consistent with the requirements of 42 U.S.C. 7384n(c).
The rule does not interfere with State, local, or tribal governments in
the exercise of their governmental functions.
B. Regulatory Flexibility Act
The Regulatory Flexibility Act (RFA), 5 U.S.C. 601 et seq.,
requires each agency to consider the potential impact of its
regulations on small entities including small businesses, small
governmental units, and small not-for-profit organizations. This rule
establishes standards for the delivery of digitally-acquired chest
radiographs for underground coal miners. It does not impose any new
requirements on small radiographic facilities that participate in the
Coal Workers' Health Surveillance Program (CWHSP) administered by NIOSH
under 42 CFR part 37. These facilities may continue to exclusively use
film-screen technology for radiography under provisions that would be
essentially unchanged by this rulemaking. The rule will benefit these
facilities by allowing and facilitating their transition to digital
radiography for the purposes of this program. In this respect, the
reliance in the rule on the DICOM standards, standard technology, and
current best practices for lung imaging radiography ensure that the
rule is consistent with current medical practices in digital
radiography. It should also be noted that if this standard permits some
facilities to switch entirely to digital imaging, rather than
maintaining two duplicate technologies, the facilities may be able to
achieve savings in radiography operating costs, as discussed in the
Executive Orders 12866 and 13563 analysis above. The final rule also
introduces a substantial benefit in allowing the participation in CWHSP
of radiography facilities that solely use digital radiography; such
facilities currently are prohibited from participation due to the
current lack of digital radiography standards for CWHSP under part 37.
This final rule is expected to increase access to medical
facilities for small and larger coal mine operators, since many medical
facilities exclusively use digital radiography or are transitioning to
this technology. The rule may also decrease the cost to coal mine
operators of providing X-ray screenings to miners. Lower cost is likely
to be one of the factors in the trend among radiography facilities to
adopt or switch entirely to digital radiography. In any event, allowing
and facilitating the provision of digital radiography under part 37
will impose no new costs on small coal mine operators.
The final rule establishes a new requirement for coal mine
operators to provide to NIOSH a roster of current miners under Sec.
37.4(a)(3). The provision of this roster to NIOSH is current practice
by almost all coal mine operators. HHS estimates that, of 488
underground coal mines that can be considered small as of the first
quarter of 2011,\3\ 130 coal mine plans are submitted to the Agency
annually. HHS further estimates that a clerical worker spends 0.5 hours
per year preparing the roster. According to the Bureau of Labor
Statistics, the average salary of a coal mine clerical worker is
$17.38/hour; HHS estimates the annual cost for an individual coal mine
operator to supply a roster to NIOSH is approximately $9 and the total
cost to all coal mines combined amounts to approximately $1170
annually. In HHS's judgment, this $9 cost would not be significant for
any coal mine operator. Therefore, a regulatory flexibility analysis as
provided for under the RFA is not required. HHS certifies that this
rule will not have a significant economic impact on a substantial
number of small entities within the meaning of the RFA.
---------------------------------------------------------------------------
\3\ U.S. Department of Labor, Mine Safety and Health
Administration. Mining Industry Accident, Injuries, Employment, and
Production Data--Address & Employment Self-Extracting Files. http://www.msha.gov/stats/part50/p50y2k/aetable.htm. Accessed June 26,
2012.
---------------------------------------------------------------------------
C. Paperwork Reduction Act
The Paperwork Reduction Act, 44 U.S.C. 3501 et seq., requires an
agency to invite public comment on, and to obtain OMB approval of, any
regulation that requires 10 or more people to report information to the
agency or to keep certain records. This final rule continues to impose
the same information collection requirements as under the current rule,
including the submission of the following forms:
[dec221] Roentgenographic Interpretation Form [CDC/NIOSH (M)2.8]
[dec221] Miner Identification Document [CDC/NIOSH (M)2.9]
[dec221] Coal Mine Operator's Plan [CDC/NIOSH (M)2.10]
[dec221] Facility Certification Document [CDC/NIOSH (M)2.11]
[dec221] Interpreting Physician Certification Document [CDC/NIOSH
(M)2.12]
[dec221] Consent, Release, and History Form [CDC/NIOSH (M)2.6]
These forms are approved by OMB for data collected under the CWHSP
(OMB Control No. 0920-0020, exp. June 30, 2014).
The additional reporting burden associated with the Coal Mine
Operator's Plan which requires underground coal mine operators to
submit a roster of current employees (Sec. 37.4(a)(3)), and the
Facility
[[Page 56725]]
Certification Document which is required of participating digital
radiography facilities (Sec. 37.44(a)(2)), are both accounted for in
the OMB information collection approval referenced above. There is no
additional recordkeeping burden associated with the quality assurance
program referenced in Sec. 37.44(g) because this provision reflects
standard industry practice and does not impose any new recordkeeping
requirements.
----------------------------------------------------------------------------------------------------------------
Number of Response
Type of respondent Form name and No. Number of responses per Hours/ burden (in
respondents respondent response hrs)
----------------------------------------------------------------------------------------------------------------
Physicians (B Readers)............ Roentgenographic 10,000 1 3/60 500
Interpretation Form--
CDC/NIOSH (M) 2.8.
Miners............................ Miner Identification 5,000 1 20/60 1,667
Document--CDC/NIOSH
(M) 2.9.
Coal Mine Operators............... Coal Mine Operator's 200 1 30/60 100
Plan--CDC/NIOSH (M)
2.10.
Super visors at X-ray Facilities.. Facility 100 1 30/60 50
Certification
Document--CDC/NIOSH
(M) 2.11.
Physicians (B Readers)............ Interpreting 300 1 10/60 50
Physician
Certification
Document--CDC/NIOSH
(M) 2.12.
Spirometry Test--Coal Miners...... No form involved..... 2,500 1 20/60 833
X-ray--Coal Miners................ No form involved..... 5,000 1 15/60 1250
Pathologist....................... (Invoice)............ 50 1 5/60 4
Pathologist....................... (Final diagnosis)... 50 1 5/60 4
Next-of-Kin....................... Consent, Release, and 50 1 15/60 13
History Form--
CDC.NIOSH (M) 2.6.
------------------------------------------------------
Totals........................ ..................... 23,250 .............. ........... 4,471
----------------------------------------------------------------------------------------------------------------
D. Small Business Regulatory Enforcement Fairness Act
As required by Congress under the Small Business Regulatory
Enforcement Fairness Act of 1996 (5 U.S.C. 801 et seq.), the Department
will report the promulgation of this rule to Congress prior to its
effective date. The report will state that the Department has concluded
that this rule is not a ``major rule'' because it is not likely to
result in an annual effect on the economy of $100 million or more.
E. Unfunded Mandates Reform Act of 1995
Title II of the Unfunded Mandates Reform Act of 1995 (2 U.S.C. 1531
et seq.) directs agencies to assess the effects of Federal regulatory
actions on State, local, and tribal governments, and the private sector
``other than to the extent that such regulations incorporate
requirements specifically set forth in law.'' For purposes of the
Unfunded Mandates Reform Act, this rule does not include any Federal
mandate that may result in increased annual expenditures in excess of
$100 million by State, local or tribal governments in the aggregate, or
by the private sector. For 2012, the inflation adjusted threshold is
$139 million.
F. Executive Order 12988 (Civil Justice)
This rule has been drafted and reviewed in accordance with
Executive Order 12988, ``Civil Justice Reform,'' and will not unduly
burden the Federal court system. Chest radiograph interpretations that
result in a finding of pneumoconiosis may be an element in claim
processing and adjudication conducted by DOL's Black Lung Compensation
Program. This final rule would affect radiographs submitted to DOL for
the purpose of reviewing and administering those claims. This rule has
been reviewed carefully to eliminate drafting errors and ambiguities.
G. Executive Order 13132 (Federalism)
The Department has reviewed this rule in accordance with Executive
Order 13132 regarding federalism, and has determined that it does not
have ``federalism implications.'' The rule does not ``have substantial
direct effects on the States, on the relationship between the national
government and the States, or on the distribution of power and
responsibilities among the various levels of government.''
H. Executive Order 13045 (Protection of Children From Environmental
Health Risks and Safety Risks)
In accordance with Executive Order 13045, HHS has evaluated the
environmental health and safety effects of this rule on children. HHS
has determined that the rule would have no effect on children.
I. Executive Order 13211 (Actions Concerning Regulations That
Significantly Affect Energy Supply, Distribution, or Use)
In accordance with Executive Order 13211, HHS has evaluated the
effects of this rule on energy supply, distribution or use, and has
determined that the rule will not have a significant adverse effect.
J. Plain Writing Act of 2010
Under Public Law 111-274 (October 13, 2010), executive Departments
and Agencies are required to use plain language in documents that
explain to the public how to comply with a requirement the Federal
Government administers or enforces. HHS has attempted to use plain
language in promulgating the final rule consistent with the Federal
Plain Writing Act guidelines.
V. Final Rule
List of Subjects in 42 CFR Part 37
Black lung benefits, Incorporation by reference, Lung diseases,
Mine safety and health, Occupational safety and health, Pneumoconiosis,
Respiratory and pulmonary diseases, Underground coal mining, Workers'
compensation, X-rays.
Text of the Rule
For the reasons discussed in the preamble, the Department of Health
and Human Services amends 42 CFR part 37 as follows:
PART 37--SPECIFICATIONS FOR MEDICAL EXAMINATIONS OF UNDERGROUND
COAL MINERS
0
1. The authority citation for part 37 continues to read as follows:
Authority: Sec. 203, 83 Stat. 763 (30 U.S.C. 843), unless
otherwise noted.
Subpart--Chest Radiographic Examinations
0
2. Revise Sec. 37.1 to read as follows:
Sec. 37.1 Scope.
The provisions of this subpart set forth the specifications for
giving, interpreting, classifying, and submitting chest radiographs
required by section 203 of the Act to be given to
[[Page 56726]]
underground coal miners and new miners.
0
3. Revise Sec. 37.2 to read as follows:
Sec. 37.2 Definitions.
Any term defined in the Federal Mine Safety and Health Act of 1977
and not defined below will have the meaning given it in the Act. As
used in this subpart:
Act means the Federal Mine Safety and Health Act of 1977 (30 U.S.C.
801, et seq.).
Chest radiograph means a single posteroanterior radiographic
projection or radiograph of the chest at full inspiration recorded on
either film or digital radiography systems.
Convenient time and place with respect to the conduct of any
examination under this subpart means that the examination must be given
at a reasonable hour in the locality in which the miner resides or a
location that is equally accessible to the miner. For example,
examinations at the mine during, immediately preceding, or immediately
following work and a ``no appointment'' examination at a medical
facility in a community easily accessible to the residences of a
majority of the miners working at the mine, will be considered of
equivalent convenience for purposes of this paragraph.
Digital radiography systems, as used in this context, include both
Digital Radiography (DR) and Computed Radiography (CR).
(1) Computed radiography (CR) is the term for digital X-ray image
acquisition systems that detect X-ray signals using a cassette-based
photostimulable storage phosphor. Subsequently, the cassette is
processed using a stimulating laser beam to convert the latent
radiographic image to electronic signals which are then processed and
stored so they can be displayed.
(2) Digital radiography (DR) is the term used for digital X-ray
image acquisition systems in which the X-ray signals received by the
image detector are converted nearly instantaneously to electronic
signals without movable cassettes.
ILO Classification means the below-referenced classification of
radiographs of the pneumoconioses system devised by an international
committee of the International Labour Office (ILO), including a
complete set of standard film radiographs or digital chest image files
available from the ILO or other set of chest image files accepted by
NIOSH as equivalent.
MSHA means the Mine Safety and Health Administration, Department of
Labor.
Miner means any individual including any coal mine construction
worker who is working in or at any underground coal mine, but does not
include any surface worker who does not have direct contact with
underground coal mining or with coal processing operations.
NIOSH means the National Institute for Occupational Safety and
Health (NIOSH), located within the Centers for Disease Control and
Prevention (CDC). Within NIOSH, the Division of Respiratory Disease
Studies (DRDS), Box 4258, Morgantown, WV 26504, formerly called the
Appalachian Laboratory for Occupational Safety and Health, is the
organizational unit that has programmatic responsibility for the chest
radiographic examination program.
NIOSH representative means employees of CDC/NIOSH and employees of
CDC contractors.
Operator means any owner, lessee, or other person who operates,
controls, or supervises an underground coal mine or any independent
contractor performing services or construction at such mine.
Panel of B Readers means the group of physicians that are currently
approved by NIOSH as B Readers.
Pre-placement physical examination means any medical examination
that includes a chest radiographic examination given in accordance with
the specifications of this Part to a person not previously employed by
the same operator. Such examinations should be conducted consistent
with applicable law, including the Americans with Disabilities Act of
1990, which provides that pre-placement examinations take place only
after an offer of employment has been made and subject to certain
restrictions (42 U.S.C. 12112(d)).
Qualified medical physicist means an individual who is trained in
evaluating the performance of radiographic equipment including
radiation controls and facility quality assurance programs, and has the
relevant current certification by a competent U.S. national board, or
unrestricted license or approval from a U.S. State or territory.
Radiographic technique chart means a table that specifies the types
of cassette, intensifying screen, film or digital detector, grid,
filter, and lists X-ray machine settings (timing, kVp, mA) that enables
the radiographer to select the correct settings based on the body
habitus or the thickness of the chest tissue.
Radiologic technologist means an individual who has met the
requirements for privileges to perform general radiographic procedures
and for competence in using the equipment and software employed by the
examining facility to obtain chest images as specified by the State or
Territory and examining facility in which such services are provided.
Optimally, such an individual will have completed a formal training
program in radiography leading to a certificate, an associate degree,
or a bachelor's degree and participated in the voluntary initial
certification and annual renewal of registration for radiologic
technologists offered by the American Registry of Radiologic
Technologists.
Secretary means the Secretary of Health and Human Services and any
other officer or employee of the Department of Health and Human
Services to whom the authority involved may be delegated.
Soft copy means the image of a coal miner's chest radiograph
acquired using a digital radiography system, viewed at the full
resolution of the image acquisition system using an electronic medical
image display device.
0
4. Revise Sec. 37.3 to read as follows:
Sec. 37.3 Chest radiographs required for miners.
(a) Voluntary examinations. Every operator must provide to each
miner who is employed in or at any of its underground coal mines and
who was employed in underground coal mining prior to December 30, 1969,
or who has completed the required examinations under Sec. 37.3(b) an
opportunity for a chest radiograph in accordance with this subpart:
(1) Following August 1, 1978 NIOSH will notify the operator of each
underground coal mine of a period within which the operator may provide
examinations to each miner employed at its coal mine. The period must
begin no sooner than October 15, 2012 and end no later than a date
specified by NIOSH separately for each coal mine. The termination date
of the period will be approximately 5 years from the date of the first
examination that was made on a miner employed by the operator in its
coal mine under the former regulations of this subpart adopted July 27,
1973. Within the period specified by NIOSH for each mine, the operator
may select a 6-month period within which to provide examinations in
accordance with a plan approved under Sec. 37.5.
Example: NIOSH finds that between July 27, 1973, and March 31,
1975, the first radiograph for a miner who was employed at mine Y
and who was employed in underground coal mining prior to December
30, 1969, was made on January 1, 1974. NIOSH will notify the
operator of mine Y that the operator may select and designate on
[[Page 56727]]
its plan a 6-month period within which to offer its examinations to
its miners employed at mine Y. The 6-month period must be scheduled
between August 1, 1978 and January 1, 1979 (5 years after January 1,
1974).
(2) For all future voluntary examinations, NIOSH will notify the
operator of each underground coal mine when sufficient time has elapsed
since the end of the previous 6-month period of examinations. NIOSH
will specify to the operator of each mine a period within which the
operator may provide examinations to its miners employed at its coal
mine. The period must begin no sooner than 3\1/2\ years and end no
later than 4\1/2\ years subsequent to the ending date of the previous
6-month period specified for a coal mine either by the operator on an
approved plan or by NIOSH if the operator did not submit an approved
plan. Within the period specified by NIOSH for each mine, the operator
may select a 6-month period within which to provide examinations in
accordance with a plan approved under Sec. 37.5.
Example: NIOSH finds that examinations were previously provided
to miners employed at mine Y in a 6-month period from July 1, 1979,
to December 31, 1979. NIOSH notifies the operator at least 3 months
before July 1, 1983 (3\1/2\ years after December 31, 1979) that the
operator may select and designate on its plan the next 6-month
period within which to offer examinations to its miners employed at
mine Y. The 6-month period must be scheduled between July 1, 1983,
and July 1, 1984 (between 3\1/2\ and 4\1/2\ years after December 31,
1979).
(3) Within either the next or future period(s) specified by NIOSH
to the operator for each of its coal mines, the operator of the coal
mine may select a different 6-month period for each of its mines within
which to offer examinations. In the event the operator does not submit
an approved plan, NIOSH will specify a 6-month period to the operator
within which miners must have the opportunity for examinations.
(b) Mandatory examinations. Every operator must provide to each
miner who begins working in or at a coal mine for the first time after
December 30, 1969:
(1) An initial chest radiograph, as soon as possible, but in no
event later than 6 months after commencement of employment. An initial
chest radiograph given to a miner according to former regulations for
this subpart prior to August 1, 1978 will also be considered as
fulfilling this requirement.
(2) A second chest radiograph, in accordance with this subpart, 3
years following the initial examination if the miner is still engaged
in underground coal mining. A second radiograph given to a miner
according to former regulations under this subpart prior to August 1,
1978 will be considered as fulfilling this requirement.
(3) A third chest radiograph 2 years following the second chest
radiograph if the miner is still engaged in underground coal mining and
if the second radiograph shows evidence of category 1 (\1/0\, \1/1\,
\1/2\), category 2 (\2/1\, \2/2\, \2/3\), category 3 (\3/2\, \3/3\, \3/
+\) simple pneumoconioses, or complicated pneumoconioses (ILO
Classification).
(c) NIOSH will notify the miner when he or she is due to receive
the second or third mandatory examination under (b) of this section.
Similarly, NIOSH will notify the coal mine operator when the miner is
to be given a second examination. The operator will be notified
concerning a miner's third examination only with the miner's written
consent, and the notice to the operator must not state the medical
reason for the examination nor that it is the third examination in the
series. If the miner is notified by NIOSH that the third mandatory
examination is due and the operator is not so notified, availability of
the radiographic examination under the Coal Mine Operator's Plan (Form
CDC/NIOSH (M)2.10) will constitute the operator's compliance with the
requirement to provide a third mandatory examination even if the miner
refuses to take the examination.
(d) The opportunity for chest radiographs to be available by an
operator for purposes of this subpart must be provided in accordance
with a plan that has been submitted and approved in accordance with
this subpart.
0
5. Amend Sec. 37.4 by revising paragraphs (a) introductory text,
(a)(3), (a)(4), (a)(6), (a)(7), and (d) through (f) to read as follows:
Sec. 37.4 Plans for chest radiographic examinations.
(a) Every plan for chest radiographic examinations of miners must
be submitted on the Coal Mine Operator's Plan form (Form CDC/NIOSH
(M)2.10) to NIOSH within 120 calendar days after August 1, 1978. In the
case of a person who after August 1, 1978, becomes an operator of a
mine for which no plan has been approved, that person must submit a
plan within 60 days after such event occurs. A separate plan must be
submitted by the operator and by each construction contractor for each
underground coal mine that has a MSHA identification number. The plan
must include:
* * * * *
(3) The proposed beginning and ending date of the 6-month period
for voluntary examinations (see Sec. 37.3(a)), the estimated number of
miners to be given or offered examinations during the 6-month period
under the plan, and a roster specifying the names and current home
mailing addresses of each miner covered by the plan;
(4) The name and location of the approved X-ray facility or
facilities, and the approximate date(s) and time(s) of day during which
the radiographs will be given to miners to enable a determination of
whether the examinations will be conducted at a convenient time and
place;
* * * * *
(6) The name and address of the A or B Reader who will interpret
and classify the chest radiographs. In the event a plan lists an
approved facility with a digital radiography system, the name and
address of the physician(s) who will perform the initial clinical
interpretation.
(7) Assurances that:
(i) The operator will not solicit a physician's radiographic or
other findings concerning any miner employed by the operator,
(ii) Instructions have been given to the person(s) giving the
examinations that duplicate radiographs or copies of radiographs
(including, for digital radiographs, copies of electronic files) will
not be made, and to the extent that it is technically feasible for the
imaging system used, digital radiographs and all related digital files
must be permanently deleted from the facility records or rendered
permanently inaccessible following the confirmed transfer of such data
to NIOSH, and that (except as may be necessary for the purpose of this
subpart) the physician's radiographic and other findings, as well as
the occupational history information obtained from a miner will not be
disclosed in a manner that would permit identification of the
individual with their information, and
(iii) The radiographic examinations will be made at no charge to
the miner.
* * * * *
(d) The operator must advise NIOSH of any change in its plan. Each
change in an approved plan is subject to the same review and approval
as the originally approved plan.
(e) The operator must promptly display in a visible location on the
bulletin board at the mine its proposed plan or proposed change in plan
when it is submitted to NIOSH. The proposed
[[Page 56728]]
plan or change in plan must remain posted in a visible location on the
bulletin board until NIOSH either grants or denies approval of it at
which time the approved plan or denial of approval must be permanently
posted. In the case of an operator who is a construction contractor and
who does not have a bulletin board, the construction contractor must
otherwise notify its employees of the examination arrangements. Upon
request, the contractor must show NIOSH written evidence that its
employees have been notified.
(f) Upon notification from NIOSH that sufficient time has elapsed
since the previous period of examinations, the operator will resubmit
its plan for each of its coal mines to NIOSH for approval for the next
period of examinations (see Sec. 37.3(a)(2)). The plan must include
the proposed beginning and ending dates of the next period of
examinations and all information required by paragraph (a) of this
section.
0
6. Revise Sec. 37.5 to read as follows:
Sec. 37.5 Approval of plans.
(a) If, after review of any plan submitted pursuant to this
subpart, the Secretary determines that the action to be taken under the
plan by the operator meets the specifications of this subpart and will
effectively achieve its purpose, the Secretary will approve the plan
and notify the operator(s) submitting the plan of the approval.
Approval may be conditioned upon such terms as the Secretary deems
necessary to carry out the purpose of Sec. 203 of the Act.
(b) Where the Secretary has reason to believe that he or she will
deny approval of a plan the Secretary will, prior to the denial, give
reasonable notice in writing to the operator(s) of an opportunity to
amend the plan. The notice must specify the ground upon which approval
is proposed to be denied.
(c) If a plan is denied approval, the Secretary must advise the
operator(s) in writing of the reasons for the denial.
0
7. Amend Sec. 37.6 by revising paragraphs (a) and (d) to read as
follows:
Sec. 37.6 Chest radiographic examinations conducted by the Secretary.
(a) The Secretary will give chest radiographs or make arrangements
with an appropriate person, agency, or institution to give the chest
radiographs and with A or B Readers to interpret the radiographs
required under this subpart in the locality where the miner resides, at
the mine, or at a medical facility easily accessible to a mining
community or mining communities, under the following circumstances:
* * * * *
(d) Operators of mines selected by NIOSH to participate in the
National Study of Coal Workers' Pneumoconiosis (an epidemiological
study of respiratory diseases in coal miners) and who agree to
cooperate will have all their miners afforded the opportunity to have a
chest radiograph required hereunder at no cost to the operator. For
future examinations and for mandatory examinations each participating
operator must submit an approvable plan.
0
8. Amend Sec. 37.7 by revising paragraph (a) to read as follows:
Sec. 37.7 Transfer of affected miner to less dusty area.
(a) Any miner who, in the judgment of the Secretary based upon the
interpretation of one or more of the miner's chest radiographs, shows
category 1 (\1/0\, \1/1\, \1/2\), category 2 (\2/1\, \2/2\, \2/3\), or
category 3 (\3/2\, \3/3\, \3/+\) simple pneumoconioses, or complicated
pneumoconioses (ILO Classification) must be afforded the option of
transferring from his or her position to another position in an area of
the mine where the concentration of respirable dust in the mine
atmosphere is in compliance with the MSHA requirements in 30 CFR 90.3.
* * * * *
0
9. Revise Sec. 37.8 to read as follows:
Sec. 37.8 Radiographic examination at miner's expense.
Any miner who wishes to obtain an examination at the miner's own
expense at an approved facility and to have the complete examination
submitted to NIOSH may do so, provided that the examination is made no
sooner than 6 months after the most recent examination of the miner
submitted to NIOSH. NIOSH will provide an interpretation and report of
the examinations made at the miner's expense in the same manner as if
it were submitted under an operator's plan. Any change in the miner's
transfer rights under the Act that may result from this examination
will be subject to the terms of Sec. 37.7.
0
10. Add Sec. 37.10 to read as follows:
Sec. 37.10 Standards incorporated by reference.
(a) Certain material is incorporated by reference into this part
with the approval of the Director of the Federal Register under 5
U.S.C. 552(a) and 1 CFR part 51. To enforce any edition other than that
specified in this section, NIOSH must publish notice of change in the
Federal Register and the material must be available to the public. All
approved material is available for inspection at NIOSH, Division of
Respiratory Disease Studies, 1095 Willowdale Road, Morgantown, WV
26505. To arrange for an inspection at NIOSH, call 304-285-5749. Copies
are also available for inspection at the National Archives and Records
Administration (NARA). For information on the availability of this
material at NARA, call 202-741-6030 or go to http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html.
(b) American Association of Physicists in Medicine, Order
Department, Medical Physics Publishing, 4513 Vernon Blvd., Madison, WI
53705, http://www.aapm.org/pubs/reports:
(1) AAPM On-Line Report No. 03, Assessment of Display Performance
for Medical Imaging Systems, April 2005, into Sec. 37.51(d) and (e).
(2) AAPM Report No. 14, Performance Specifications and Acceptance
Testing for X-Ray Generators and Automatic Exposure Control Devices,
Report of the Diagnostic X-Ray Imaging Committee Task Group on
Performance Specifications and Acceptance Testing for X-Ray Generators
and Automatic Exposure Control Devices, published by the American
Institute of Physics for AAPM, January 1985, into Sec. Sec. 37.42(h)
and 37.44(g).
(3) AAPM Report No. 31, Standardized Methods for Measuring
Diagnostic X-Ray Exposures, Report of Task Group 8, Diagnostic X-Ray
Imaging Committee, published by the American Institute of Physics, July
1990, into Sec. 37.44(g).
(4) AAPM Report No. 74, Quality Control in Diagnostic Radiology,
Report of Task Group 12, Diagnostic X-Ray Imaging Committee, published
by Medical Physics Publishing for AAPM, July 2002, into Sec. Sec.
37.42(h), 37.43(f), and 37.44(g).
(5) AAPM Report No. 93, Acceptance Testing and Quality Control of
Photostimulable Storage Phosphor Imaging Systems, October 2006, into
Sec. Sec. 37.42(i) and 37.44(g).
(6) AAPM Report No. 116, An Exposure Indicator for Digital
Radiography, Report of AAPM Task Group 116, published by AAPM, July
2009, into Sec. 37.44(g).
(c) American College of Radiology, 1891 Preston White Dr., Reston,
VA 20191, http://www.acr.org/~/media/ACR/Documents/PGTS/guidelines/
Reference--Levels.pdf:
[[Page 56729]]
(1) ACR Practice Guideline for Diagnostic Reference Levels in
Medical X-Ray Imaging, Revised 2008 (Resolution 3), into Sec. Sec.
37.42(i) and 37.44(g).
(2) [Reserved]
(d) International Labour Office, CH-1211 Geneva 22, Switzerland,
http://www.ilo.org/publns:
(1) Guidelines for the Use of the ILO International Classification
of Radiographs of Pneumoconioses, Revised Edition 2011, into Sec. Sec.
37.50(a), 37.50(c), and 37.51(b).
(2) [Reserved]
(e) National Council on Radiation Protection and Measurements, NCRP
Publications, 7910 Woodmont Avenue, Suite 400, Bethesda, MD 20814-3095,
Telephone (800) 229-2652, http://www.ncrppublications.org:
(1) NCRP Report No. 102, Medical X-ray, Electron Beam, and Gamma-
Ray Protection for Energies Up to 50 MeV (Equipment Design,
Performance, and Use), issued June 30, 1989, into Sec. 37.45.
(2) NCRP Report No. 105, Radiation Protection for Medical and
Allied Health Personnel, issued October 30, 1989, into Sec. 37.45.
(3) NCRP Report No. 147, Structural Shielding Design for Medical X-
Ray Imaging Facilities, revised March 18, 2005, into Sec. 37.45.
(f) National Electrical Manufacturers Association, 1300 N. 17th
Street, Rosslyn, VA 22209, http://medical.nema.org:
(1) DICOM Standard PS 3.3-2011, Digital Imaging and Communications
in Medicine (DICOM) standard, Part 3: Information Object Definitions,
copyright 2011, into Sec. 37.42(i).
(2) DICOM Standard PS3.4-2011, Digital Imaging and Communications
in Medicine (DICOM) standard, Part 4: Service Class Specifications,
copyright 2011, into Sec. 37.42(i).
(3) DICOM Standard PS 3.10-2011, Digital Imaging and Communications
in Medicine (DICOM) standard, Part 10: Media Storage and File Format
for Media Interchange, copyright 2011, into Sec. 37.42(i).
(4) DICOM Standard PS 3.11-2011, Digital Imaging and Communications
in Medicine (DICOM) standard, Part 11: Media Storage Application
Profiles, copyright 2011, into Sec. 37.42(i).
(5) DICOM Standard PS 3.12-2011, Digital Imaging and Communications
in Medicine (DICOM) standard, Part 12: Media Formats and Physical Media
for Media Interchange, copyright 2011, into Sec. Sec. 37.42(i) and
37.44(a).
(6) DICOM Standard PS 3.14-2011, Digital Imaging and Communications
in Medicine (DICOM) standard, Part 14: Grayscale Standard Display
Function, copyright 2011, into Sec. Sec. 37.42(i)(5) and 37.51(d).
(7) DICOM Standard PS 3.16-2011, Digital Imaging and Communications
in Medicine (DICOM) standard, Part 16: Content Mapping Resource,
copyright 2011, Sec. 37.42(i).
0
11. Revise Sec. 37.20 to read as follows:
Sec. 37.20 Miner identification document.
As part of the radiographic examination, a Miner Identification
Document (Form CDC/NIOSH (M)2.9) which includes an occupational history
questionnaire must be completed for each miner at the facility where
the radiograph is made at the same time the chest radiograph required
by this subpart is given.
0
12. Revise the undesignated center heading and Sec. 37.40 to read as
follows:
Specifications for Performing Chest Radiographic Examinations
Sec. 37.40 General provisions.
(a) The chest radiographic examination must be given at a
convenient time and place.
(b) The chest radiographic examination consists of the chest
radiograph, and a complete Roentgenographic Interpretation Form (Form
CDC/NIOSH (M)2.8), and Miner Identification Document (Form CDC/NIOSH
(M)2.9).
(c) A radiographic examination must be made in a facility approved
in accordance with Sec. 37.43 or Sec. 37.44. Chest radiographs of
miners under this section must be performed:
(1) By or under the supervision of a physician who makes chest
radiographs in the normal course of practice and who has demonstrated
ability to make chest radiographs of a quality to best ascertain the
presence of pneumoconiosis; or
(2) By a radiologic technologist as defined in Sec. 37.2.
0
13. Amend Sec. 37.41 as follows:
0
a. Revise the section heading.
0
b. Redesignate paragraphs (a) and (b) as paragraphs (b) and (a)
respectively.
0
c. Redesignate paragraphs (c) through (m) as (d) through (n).
0
d. Add new paragraph (c).
0
e. Revise newly designated paragraphs (a), (b), (d) through (h), (i)
introductory text, (i)(1) through (i)(3), (i)(7), (j)(2), (k), (m), and
(n) to read as follows:
Sec. 37.41 Chest radiograph specifications--film.
(a) Miners must be disrobed from the waist up at the time the
radiograph is given. The facility must provide a dressing area and for
those miners who wish to use one, the facility will provide a clean
gown. Facilities must be heated to a comfortable temperature.
(b) Every chest radiograph must be a single posteroanterior
projection at full inspiration on a film being no less than 14 by 17
inches and no greater than 16 by 17 inches. The film and cassette must
be capable of being positioned both vertically and horizontally so that
the chest radiograph will include both apices and costophrenic angles.
If a miner is too large to permit the above requirements, then the
projection must include both apices with minimum loss of the
costophrenic angle.
(c) Chest radiographs of miners under this section must be
performed:
(1) By or under the supervision of a physician who makes chest
radiographs in the normal course of practice and who has demonstrated
ability to make chest radiographs of a quality to best ascertain the
presence of pneumoconiosis; or
(2) By a radiologic technologist as defined in Sec. 37.2.
(d) Radiographs must be made with a diagnostic X-ray machine with a
maximum actual (not nominal) source (focal spot) of 2 mm, as measured
in two orthogonal directions.
(e) Except as provided in this paragraph (e), radiographs must be
made with units having generators that comply with the following:
(1) The generators of existing radiographic units acquired by the
examining facility prior to July 27, 1973, must have a minimum rating
of 200 mA at 100 kVp;
(2) Generators of units acquired subsequent to that date must have
a minimum rating of 300 mA at 125 kVp.
(f) Radiographs made with battery-powered mobile or portable
equipment must be made with units having a minimum rating of 100 mA at
110 kVp at 500 Hz, or of 200 mA at 110 kVp at 60 Hz.
(g) Capacitor discharge and field emission units may be used if the
model of such units is approved by NIOSH for quality, performance, and
safety. NIOSH will consider such units for approval when listed by a
facility seeking approval under Sec. Sec. 37.43 or 37.44.
(h) Radiographs must be given only with equipment having a beam-
limiting device that does not cause large unexposed boundaries. The
beam limiting device must provide rectangular collimation and must be
of the type described in 21 CFR 1020.31(d), (e), (f), and (g). The use
of such a device must be discernible from an examination of the
radiograph.
(i) To ensure high quality chest radiographs:
[[Page 56730]]
(1) The maximum exposure time must not exceed 50 milliseconds
except that with single phase units with a rating less than 300 mA at
125 kVp and subjects with chests over 28 cm posteroanterior, the
exposure may be increased to not more than 100 milliseconds;
(2) The source or focal spot to film distance must be at least 6
feet;
(3) Medium speed film and medium speed intensifying screens are
recommended. However, any film-screen combination, the rated ``speed''
of which is at least 100 and does not exceed 300, that produces
radiographs with spatial resolution, contrast, latitude and quantum
mottle similar to those of systems designated as ``medium speed'' may
be employed;
* * * * *
(7) A suitable grid or other means of reducing scattered radiation
must be used;
* * * * *
(j) * * *
(2) If mineral or other impurities in the processing water
introduce difficulty in obtaining a high-quality radiograph, a suitable
filter or purification system must be used.
(k) Before the miner is advised that the examination is concluded,
the radiograph must be processed and inspected and accepted for quality
by the physician, or if the physician is not available, acceptance may
be made by the radiologic technologist. In a case of a substandard
radiograph, another must be immediately made. All substandard
radiographs must be clearly marked as rejected and promptly sent to
NIOSH for disposal.
* * * * *
(m) A test object may be required on each radiograph for an
objective evaluation of film quality at the discretion of NIOSH.
(n)(1) Each radiograph made hereunder must be permanently and
legibly marked with:
(i) The name and address or NIOSH approval number of the facility
at which it is made;
(ii) The miner's Social Security number;
(iii) The miner's date of birth; and
(iv) The date of the radiograph.
(2) No other identifying markings may be recorded on the
radiograph.
Sec. Sec. 37.42 and 37.43 [Redesignated as Sec. Sec. 37.43 and
37.45]
0
14a. Redesignate Sec. 37.42 and Sec. 37.43 as Sec. 37.43 and Sec.
37.45 respectively.
0
14b. Add new Sec. 37.42 to read as follows:
Sec. 37.42 Chest radiograph specifications--digital radiography
systems.
(a) Miners must be disrobed from the waist up at the time the
radiograph is given. The facility must provide a private dressing area
and for those miners who wish to use one, the facility must provide a
clean gown. Facilities must be heated to a comfortable temperature.
(b) Every digital chest radiograph taken as required under this
section must be a single posteroanterior projection at full inspiration
on a digital detector with sensor area being no less than 1505 cm
square centimeters with a minimum width of 35cm. The imaging plate must
have a maximum pixel pitch of 200[mu]m, with a minimum bit depth of 10.
Spatial resolution must be at least 2.5 line pairs per millimeter. The
storage phosphor cassette or digital image detector must be positioned
either vertically or horizontally so that the image includes the apices
and costophrenic angles of both right and left lungs. If the detector
cannot include the apices and costophrenic angles of both lungs as
described, then two side-by-side images can be obtained that together
include the apices and the costophrenic angles of both right and left
lungs.
(c) Chest radiographs of miners under this section must be
performed:
(1) By or under the supervision of a physician who makes chest
radiographs in the normal course of practice and who has demonstrated
ability to make chest radiographs of a quality to best ascertain the
presence of pneumoconiosis; or
(2) By a radiologic technologist as defined in Sec. 37.2.
(d) Radiographs must be made with a diagnostic X-ray machine with a
maximum actual (not nominal) source (focal spot) of 2 mm, as measured
in two orthogonal directions.
(e) Radiographs must be made with units having generators which
have a minimum rating of 300 mA at 125 kVp. Exposure kilovoltage must
be at least the minimum as recommended by the manufacturer for chest
radiography.
(f) An electric power supply must be used that complies with the
voltage, current, and regulation specified by the manufacturer of the
machine. If the manufacturer or installer of the radiographic equipment
recommends equipment for control of electrical power fluctuations, such
equipment must be used as recommended.
(g) Radiographs must be obtained only with equipment having a beam-
limiting device that does not cause large unexposed boundaries. The
beam limiting device must provide rectangular collimation. Electronic
post-image acquisition ``shutters'' available on some CR and DR systems
that limit the size of the final image and that simulate collimator
limits must not be used. The use and effect of the beam limiting device
must be discernible on the resulting image.
(h) Radiographic technique charts must be used that are developed
specifically for the X-ray system and detector combinations used,
indicating exposure parameters by anatomic measurements.
(1) If automated exposure control devices are used, performance
must be documented by a medical physicist utilizing the image capture
systems and exposure parameters used at the facility for chest imaging,
using methods recommended in AAPM Report No. 74, pages 17-18, and in
AAPM Report No. 14, pages 61-62 (incorporated by reference, see Sec.
37.10).
(2) Exposure parameters achieved during the evaluation of the
automated exposure system must be recorded by the medical physicist in
a written report or electronic file that is stored at the facility and
available for inspection by NIOSH for a minimum of 5 years after the
miner's examination.
(i) To ensure high quality digital chest radiographs:
(1) The maximum exposure time must not exceed 50 milliseconds
except for subjects with chests over 28 centimeters posteroanterior,
for whom the exposure time must not exceed 100 milliseconds;
(2) The distance from source or focal spot to detector must be at
least 70 inches (or 180 centimeters if measured in centimeters);
(3) The exposure setting for chest images must be within the range
of 100-300 equivalent exposure speeds and must comply with ACR Practice
Guideline for Diagnostic Reference Levels in Medical X-Ray Imaging,
Section V--Diagnostic Reference Levels For Imaging With Ionizing
Radiation and Section VII--Radiation Safety in Imaging (incorporated by
reference, see Sec. 37.10). Radiation exposures should be periodically
measured and patient radiation doses estimated by the medical physicist
to assure doses are as low as reasonably achievable.
(4) Digital radiography system performance, including resolution,
modulation transfer function (MTF), image signal-to-noise and detective
quantum efficiency must be evaluated and judged acceptable by a
qualified medical physicist using the specifications in AAPM Report No.
93, pages 1-68 (incorporated by reference, see Sec. 37.10). Image
management software and settings for routine chest
[[Page 56731]]
imaging must be used, including routine amplification of digital
detector signal as well as standard image post-processing functions.
Image or edge enhancement software functions must not be employed
unless they are integral to the digital radiography system (not
elective); in such cases, only the minimum image enhancement permitted
by the system may be employed.
(5)(i) The image object, transmission and associated data storage,
file format, and transmission of associated information must conform to
the following components of the Digital Imaging and Communications in
Medicine (DICOM) standard (incorporated by reference, see Sec. 37.10):
(A) DICOM Standard PS 3.3-2011, Annex A--Composite Information
Object Definitions, sections: Computed Radiography Image Information
Object Definition; Digital X-Ray Image Information Object Definition;
X-Ray Radiation Dose SR Information Object Definition; and Grayscale
Softcopy Presentation State Information Object Definition.
(B) DICOM Standard PS3.4-2011, Annex B--Storage Service Class;
Annex N--Softcopy Presentation State Storage SOP Classes; Annex O--
Structured Reporting Storage SOP Classes.
(C) DICOM Standard PS 3.10-2011.
(D) DICOM Standard PS 3.11-2011
(E) DICOM Standard PS 3.12-2011.
(F) DICOM Standard PS 3.14-2011.
(G) DICOM Standard PS 3.16-2011.
(ii) Identification of each miner, chest image, facility, date and
time of the examination must be encoded within the image information
object, according to DICOM Standard PS 3.3-2011, Information Object
Definitions, for the DICOM ``DX'' object. If data compression is
performed, it must be lossless. Exposure parameters (kVp, mA, time,
beam filtration, scatter reduction, radiation exposure) must be stored
in the DX information object.
(iii) Exposure parameters as defined in the DICOM Standard PS 3.16-
2011 must additionally be provided, when such parameters are available
from the facility digital image acquisition system or recorded in a
written report or electronic file and either transmitted to NIOSH or
stored at the facility and available for inspection by NIOSH for 5
years after the examination.
(6) A specific test object may be required on each radiograph for
an objective evaluation of image quality at the discretion of NIOSH.
(7) CR imaging plates must be inspected at least once a month and
cleaned when necessary by the method recommended by the manufacturer;
(8) A grid or air gap for reducing scattered radiation must be
used; grids must not be used that cause Moir[eacute] interference
patterns in either horizontal or vertical images.
(9) The geometry of the radiographic system must ensure that the
central axis (ray) of the primary beam is perpendicular to the plane of
the CR imaging plate, or DR detector and is correctly aligned to the
grid;
(10) Radiographs must not be made when the environmental
temperatures and humidity in the facility are outside the
manufacturer's recommended range of the CR and DR equipment to be used.
(11) Before the miner is advised that the examination is concluded,
the radiograph must be processed and inspected and accepted for quality
by the physician, or if the physician is not available, acceptance may
be made by the radiologic technologist. In a case of a substandard
radiograph, another must be made immediately. Unacceptable digital
image files must be fully deleted immediately or rendered permanently
inaccessible in the event that permanent deletion is not
technologically feasible.
(j) The following are not authorized for use under this section:
(1) Digital images derived from film screen chest radiographs
(e.g., by scanning or digital photography); or
(2) Images that were acquired using digital systems and then
printed on transparencies for back-lighted display (e.g., using
tradition view boxes).
0
15. Revise newly designated Sec. 37.43 to read as follows:
Sec. 37.43 Approval of radiographic facilities that use film.
(a) Facilities become eligible to participate in this program by
demonstrating their ability to make high quality diagnostic chest
radiographs by submitting to NIOSH six or more sample chest radiographs
made and processed at the applicant facility and which are of
acceptable quality to one or more individuals selected by NIOSH from
the panel of B Readers. Applicants must also submit a radiograph of a
plastic step-wedge object \1\ or other test object (available on loan
from NIOSH) that was made and processed at the same time with the same
technique as the radiographs submitted and processed at the facility
for which approval is sought. At least one chest radiograph and one
test object radiograph must have been made with each unit to be used
hereunder. All radiographs must have been made within 15 calendar days
prior to submission and must be marked to identify the facility where
each radiograph was made, the X-ray machine used, and the date each was
made. The chest radiographs will be returned and may be the same
radiographs submitted pursuant to Sec. 37.50.
---------------------------------------------------------------------------
\1\ The plastic step-wedge object is described in Trout ED,
Kelley JP [1973]. A phantom for the evaluation of techniques and
equipment used for roentgenography of the chest. Amer J Roentgenol
117(4):771-776.
---------------------------------------------------------------------------
(b) Each radiographic facility submitting chest radiographs for
approval under this section must complete and include an X-ray Facility
Certification Document (Form CDC/NIOSH (M) 2.11) describing each X-ray
unit to be used to make chest radiographs under the Act. The form must
include:
(1) The date of the last radiation safety inspection by an
appropriate licensing agency or, if no such agency exists, by a
qualified expert as defined in NCRP Report No. 102 (incorporated by
reference, see Sec. 37.10);
(2) The deficiencies found;
(3) A statement that all the deficiencies have been corrected; and
(4) The date of acquisition of the X-ray unit. To be acceptable,
the radiation safety inspection must have been made within 1 year
preceding the date of application.
(c) Radiographs submitted with applications for approval under this
section will be evaluated by one or more individuals selected by NIOSH
from the panel of B Readers or by a qualified medical physicist or
consultant. Applicants will be advised of any reasons for denial of
approval.
(d) NIOSH or its representatives may make a physical inspection of
the applicant's facility and any approved radiographic facility at any
reasonable time to determine if the requirements of this subpart are
being met.
(e) NIOSH may require a facility periodically to resubmit
radiographs of a test object, sample radiographs, or a Facility
Certification Document for quality control purposes. Approvals granted
hereunder may be suspended or withdrawn by notice in writing when in
the opinion of NIOSH the quality of radiographs or information
submitted under this section warrants such action. A copy of a notice
withdrawing approval will be sent to each operator who has listed the
facility as its facility for giving chest radiographs and must be
displayed on the mine bulletin board adjacent to the operator's
approved plan. The approved plan will be reevaluated by NIOSH in light
of this change.
(f) A formal written quality assurance program must be established
at each facility addressing radiation exposures, equipment maintenance,
and image
[[Page 56732]]
quality, and must conform to the standards in AAPM Report No. 74, pages
1-19, 47-53, and 56 (incorporated by reference, see Sec. 37.10).
(g) In conducting medical examinations pursuant to this Part,
physicians and radiographic facilities must maintain the results and
analysis of these examinations (including any hard copies or digital
files containing individual data, interpretations, and images)
consistent with applicable statutes and regulations governing the
treatment of individually identifiable health information, including,
as applicable, the HIPAA Privacy and Security Rules (45 CFR part 160
and subparts A, C, and E of part 164).
0
16. Add Sec. 37.44 to read as follows:
Sec. 37.44 Approval of radiographic facilities that use digital
radiography systems.
(a) Applications for facility approval. (1) Facilities seeking
approval must demonstrate the ability to make high quality digital
chest radiographs by submitting to NIOSH digital radiographic image
files of a test object (e.g., a plastic step-wedge or chest phantom
which will be provided on loan from NIOSH) as well as digital
radiographic image files from six or more sample chest radiographs that
are of acceptable quality to one or more individuals selected by NIOSH
from the panel of B Readers and a qualified medical physicist or
consultant, both designated by NIOSH. Image files must be submitted on
standard portable media (compact or digital video disc) and formatted
to meet specifications of the Digital Imaging and Communications in
Medicine (DICOM) standard PS 3.12-2011 (incorporated by reference, see
Sec. 37.10). Applicants will be advised of any reasons for denial of
approval. All submitted images must be made within 60 days prior to the
date of application using the same technique, equipment, and software
as will be used by the facility under the requested approval. At least
six chest radiographs and one test object radiograph must have been
made with each digital radiographic unit to be used by the facility
under the requested approval. The corresponding radiographic image
files must be submitted on standard portable media (compact or digital
video disc) and formatted to meet specifications of the current DICOM
Standard PS 3.12-2011. Documentation must include the following: the
identity of the facility where each radiograph was made; the X-ray
machine used; and the model, version, and production date of each image
acquisition software program and hardware component. The submitted
sample digital chest image files must include at least two taken with
the detector in the vertical position and two in the horizontal
position where the imaging system permits these positions, and at least
two chest images must be from persons within the highest quartile of
chest diameters (28 cm or greater).
(2) Each radiographic facility submitting chest radiographic image
files for approval under this section must complete and include an X-
ray Facility Certification Document (Form CDC/NIOSH (M)2.11) describing
each X-ray system component, and the models and versions of image
acquisition hardware and software to be used to make digital chest
radiographs under the Act. The form must include:
(i) A copy of a dated report signed by a qualified medical
physicist, documenting the evaluation of radiation safety and
performance characteristics specified in this section for each digital
radiography system;
(ii) A copy of the report of the most recent radiation safety
inspection by a licensing agency, if such agency exists;
(iii) A listing of all deficiencies noted in either of the reports;
(iv) A statement that all the listed deficiencies have been
corrected; and
(v) The names and relevant training and experience of facility
personnel described in paragraphs (b), (d), and (e) of this section. To
be acceptable, the report by the medical physicist and radiation safety
inspection specified in this paragraph must have been made within 1
year prior to the date of submission of the application.
(b) Facilities must maintain ongoing licensure and certification
under relevant local, State, and Federal laws and regulations for all
digital equipment and related processes covered under this part.
(c) NIOSH or its representatives may make a physical inspection of
the applicant's facility and any approved radiographic facility at any
reasonable time to determine if the requirements of this subpart are
being met.
(d) NIOSH may periodically require a facility to resubmit
radiographic image files of the NIOSH-supplied test object (e.g., step-
wedge or chest phantom), sample radiographs, or a Facility
Certification Document. Approvals granted to facilities under this
section may be suspended or withdrawn by notice in writing when, in the
opinion of NIOSH, deficiencies in the quality of radiographs or
information submitted under this section warrant such action. A copy of
a notice suspending or withdrawing approval will be sent to each
operator that has listed the facility for its use under this Part and
must be displayed on the mine bulletin board adjacent to the operator's
approved plan. The operator's approved plan may be reevaluated by NIOSH
in response to such suspension or withdrawal.
(e) A qualified medical physicist who is familiar with the facility
hardware and software systems for image acquisition, manipulation,
display, and storage, must be on site or available as a consultant. The
physicist must be trained in evaluating the performance of radiographic
equipment and facility quality assurance programs, and must be
licensed/approved by a State or Territory of the United States or
certified by a competent U.S. national board.
(f) Facilities must document that testing performed by a qualified
medical physicist has verified that performance of each image
acquisition system for which approval is sought met initial
specifications and standards of the equipment manufacturer and
performance testing as required under paragraphs (b), (e), and (g) of
this section.
(g) A formal written quality assurance program must be established
at each facility addressing radiation exposures, equipment maintenance,
and image quality, and must conform to the standards in AAPM Report No.
74, pages 1-19, 47-53, and 56, and AAPM Report No. 116, sections VIII,
IX, and X (incorporated by reference, see Sec. 37.10).
(1) Applications for facility approval must include a comprehensive
assessment by a qualified medical physicist within 12 months prior to
application addressing the performance of X-ray generators, automatic
exposure controls, and image capture systems. The assessment must
comply with the following guidelines: AAPM Report No. 93, pages 1-68;
AAPM Report No. 74, pages 6-11; and AAPM Report No. 14, pages 1-96
(incorporated by reference, see Sec. 37.10).
(2) Radiographic technique charts must be used that are developed
specifically for the X-ray system and detector combinations used,
indicating exposure parameters by anatomic measurements. If automated
exposure control devices are used, calibration for chest imaging must
be documented using the actual voltages and image capture systems.
Radiological exposures resulting from at least ten (randomly selected)
digital chest images obtained at the facility must be monitored at
least quarterly to detect and correct potential dose creep, using
methods specified in AAPM Report No. 31 (incorporated by reference, see
Sec. 37.10). Radiation exposures must be compared to a professionally
accepted reference level
[[Page 56733]]
published in the American College of Radiology (ACR) Practice Guideline
for Diagnostic Reference Levels in Medical X-Ray Imaging, pages 1-6
(incorporated by reference, see Sec. 37.10). In addition, the medical
physicist must submit an annual assessment of measured or estimated
radiation exposures, with specific recommended actions to minimize
exposures during examinations performed under this part.
(3) For each digital radiography device and system, performance
must be monitored annually in accordance with the recommendations of
AAPM Report No. 93 (incorporated by reference, see Sec. 37.10), except
for the testing specifically excluded below. Documentation must be
maintained on the completion of quality assurance testing, including
the reproducibility of X-ray output, linearity and reproducibility of
mA settings, accuracy and reproducibility of timer and kVp settings,
accuracy of source-to-detector distance, and X-ray field focal spot
size, selection, beam quality, congruence and collimation. For DR
systems, the following tests listed in AAPM Report No. 93 are not
required under this part:
(i) Section 8.4.5: Laser beam function
(ii) Section 8.4.9: Erasure Thoroughness
(iii) Section 8.4.11: Imaging Plate (IP) Throughput
(4) Facilities must maintain documentation, available for
inspection by NIOSH for 5 years, of the ongoing implementation of
policies and procedures for monitoring and evaluating the effective
management, safety, and proper performance of chest image acquisition,
digitization, processing, compression, transmission, display,
archiving, and retrieval functions of digital radiography devices and
systems.
(h) In conducting medical examinations pursuant to this Part,
physicians and radiographic facilities must maintain the results and
analysis of these examinations (including any hard copies or digital
files containing individual data, interpretations, and images)
consistent with applicable statutes and regulations governing the
treatment of individually identifiable health information, including,
as applicable, the HIPAA Privacy and Security Rules (45 CFR Part 160
and Subparts A, C, and E of Part 164).
0
17. Revise newly designated Sec. 37.45 to read as follows:
Sec. 37.45 Protection against radiation emitted by radiographic
equipment.
Except as otherwise specified in Sec. 37.41 and Sec. 37.42,
radiographic equipment, its use and the facilities (including mobile
facilities) in which such equipment is used, must conform to applicable
State or Territorial and Federal regulations. Where no applicable
regulations exist, radiographic equipment, its use and the facilities
(including mobile facilities) in which such equipment is used must
conform to the recommendations in NCRP Report No. 102, NCRP Report No.
105, and NCRP Report No. 147 (incorporated by reference, see Sec.
37.10).
0
18. Revise the undesignated center heading and Sec. 37.50 to read as
follows:
Specifications for Interpretation, Classification, and Submission of
Chest Radiographs
Sec. 37.50 Interpreting and classifying chest radiographs--film.
(a) Chest radiographs must be interpreted and classified in
accordance with the Guidelines for the Use of the ILO International
Classification of Radiographs of Pneumoconioses (incorporated by
reference, see Sec. 37.10). Chest radiograph interpretations and
classifications must be recorded on a paper or electronic
Roentgenographic Interpretation Form (Form CDC/NIOSH (M)2.8).
(b) Radiographs must be interpreted and classified only by a
physician who reads chest radiographs in the normal course of practice
and who has demonstrated proficiency in classifying the pneumoconioses
in accordance with Sec. 37.52.
(1) Initial clinical interpretations and notification of findings
other than pneumoconiosis under Sec. 37.50(a) must be provided by a
qualified physician who has all required licensure and privileges, and
interprets chest radiographs in the normal course of practice.
(2) [Reserved]
(c) All interpreters, whenever interpreting chest radiographs made
under the Act, must have immediately available for reference a complete
set of the standard radiographs for use with the Guidelines for the Use
of the ILO International Classification of Radiographs of
Pneumoconioses (incorporated by reference, see Sec. 37.10).
(d) In all view boxes used for making interpretations:
(1) Fluorescent lamps must be simultaneously replaced with new
lamps at 6-month intervals;
(2) All the fluorescent lamps in a panel of boxes must have
identical manufacturer's ratings as to intensity and color;
(3) The glass, internal reflective surfaces, and the lamps must be
kept clean;
(4) The unit must be so situated as to minimize front surface
glare.
Sec. Sec. 37.51 through 37.53 [Redesignated as Sec. Sec. 37.52
through 37.54]
0
19a. Redesignate Sec. 37.51 through Sec. 37.53 as Sec. 37.52 through
Sec. 37.54 respectively.
0
19b. Add new Sec. 37.51 to read as follows:
Sec. 37.51 Interpreting and classifying chest radiographs--digital
radiography systems.
(a) For each chest radiograph obtained at an approved facility
using a digital radiography system, a qualified and licensed physician
who reads chest radiographs in the normal course of practice must
provide an initial clinical interpretation and notification, as
specified in Sec. 37.54, of any significant abnormal findings other
than pneumoconiosis.
(b) Chest radiographs must be classified for pneumoconiosis by
physician readers who have demonstrated ongoing proficiency, as
specified in Sec. 37.52(b), in classifying the pneumoconioses in a
manner consistent with the Guidelines for the Use of the ILO
International Classification of Radiographs of Pneumoconioses
(incorporated by reference, see Sec. 37.10). Chest radiograph
interpretations and classifications must be recorded on a paper or
electronic Roentgenographic Interpretation Form (Form CDC/NIOSH
(M)2.8).
(c) All interpreters, whenever classifying digitally-acquired chest
radiographs made under the Act, must have immediately available for
reference a complete set of NIOSH-approved standard digital chest
radiographic images provided for use with the Guidelines for the Use of
the ILO International Classification of Radiographs of Pneumoconioses
(incorporated by reference, see Sec. 37.10). Only NIOSH-approved
standard digital images may be used for classifying digital chest
images for pneumoconiosis. Modification of the appearance of the
standard images using software tools is not permitted.
(d) Viewing systems should enable readers to display the coal
miner's chest image at the full resolution of the image acquisition
system, side-by-side with the selected NIOSH-approved standard images
for comparison.
(1)(i) Image display devices must be flat panel monitors displaying
at least 3 MP at 10 bit depth. Image displays and associated graphics
cards must meet the calibration and other specifications of the Digital
Imaging and Communications in Medicine (DICOM)
[[Page 56734]]
standard PS 3.14-2011 (incorporated by reference, see Sec. 37.10).
(ii) Image displays and associated graphics cards must not deviate
by more than 10 percent from the grayscale standard display function
(GSDF) when assessed according to the AAPM On-Line Report No. 03, pages
1-146 (incorporated by reference, see Sec. 37.10).
(2) Display system luminance (maximum and ratio), relative noise,
linearity, modulation transfer function (MTF), frequency, and glare
should meet or exceed recommendations listed in AAPM On-Line Report No.
03, pages 1-146 (incorporated by reference, see Sec. 37.10). Viewing
displays must have a maximum luminance of at least 171 cd/m\2\, a ratio
of maximum luminance to minimum luminance of at least 250, and a glare
ratio greater than 400. The contribution of ambient light reflected
from the display surface, after light sources have been minimized, must
be included in luminance measurements.
(3) Displays must be situated so as to minimize front surface
glare. Readers must minimize reflected light from ambient sources
during the performance of classifications.
(4) Measurements of the width and length of pleural shadows and the
diameter of opacities must be taken using calibrated software measuring
tools. If permitted by the viewing software, a record must be made of
the presentation state(s), including any noise reduction and edge
enhancement or restoration functions that were used in performing the
classification, including any annotations and measurements.
(e) Quality control procedures for devices used to display chest
images for classification must comply with the recommendations of the
American Association of Physicists in Medicine AAPM On-Line Report No.
03, pages 1-146 (incorporated by reference, see Sec. 37.10).
(1) If automatic quality assurance systems are used, visual
inspection must be performed using one or more test patterns
recommended by the medical physicist every 6 months, or more
frequently, to check for defects that automatic systems may not detect.
(2) [Reserved]
(f) Classification of CR and DR digitally-acquired chest
radiographs under this Part must be performed based on the viewing of
images displayed as soft copies using the viewing workstations
specified in this section. Classification of radiographs must not be
based on the viewing of hard copy printed transparencies of images that
were digitally-acquired.
(g) The classification of chest radiographs based on digitized
copies of chest radiographs that were originally acquired using film-
screen techniques is not permissible under this part.
0
20. Revise newly designated Sec. 37.52 to read as follows:
Sec. 37.52 Proficiency in the use of systems for classifying the
pneumoconioses.
(a) First or A Readers:
(1) Approval as an A Reader must continue if established prior to
October 15, 2012.
(2) Physicians who desire to be A Readers must demonstrate their
proficiency in classifying the pneumoconioses by either:
(i) Submitting to NIOSH from the physician's files six sample chest
radiographs which are considered properly classified by one or more
individuals selected by NIOSH from the panel of B Readers. The six
radiographs must consist of two without pneumoconiosis, two with simple
pneumoconiosis, and two with complicated pneumoconiosis (these may be
the same radiographs submitted for facility approval pursuant to Sec.
37.43 and Sec. 37.44). The films will be returned to the physician.
The interpretations must be on the Roentgenographic Interpretation Form
(Form CDC/NIOSH (M)2.8), or;
(ii) Satisfactory completion, since June 11, 1970, of a course
approved by NIOSH on the ILO International Classification of
Radiographs of Pneumoconioses.
(b) Final or B Readers:
(1) Approval as a B Reader established prior to October 1, 1976, is
hereby terminated.
(2) Proficiency in evaluating chest radiographs for radiographic
quality and in the use of the ILO Classification for interpreting chest
radiographs for pneumoconiosis and other diseases must be demonstrated
by those physicians who desire to be B Readers by taking and passing a
specially-designed proficiency examination given on behalf of or by
NIOSH at a time and place specified by NIOSH. Each physician who
desires to take the digital version of the examination will be provided
a complete set of the current NIOSH-approved standard reference digital
radiographs. Physicians who qualify under this provision need not be
qualified under paragraph (a) of this section.
(c) Physicians who wish to participate in the program must
familiarize themselves with the necessary components for attainment of
reliable classification of chest radiographs for the pneumoconioses \2\
and apply using an Interpreting Physician Certification Document (Form
CDC/NIOSH (M)2.12).
---------------------------------------------------------------------------
\2\ NIOSH Safety and Health Topic. Chest Radiography:
Radiographic Classification [http://www.cdc.gov/niosh/topics/chestradiography/radiographic-classification.html]. Date accessed:
June 27, 2012.
0
21. Revise newly designated Sec. 37.53 to read as follows:
Sec. 37.53 Method of obtaining definitive interpretations.
(a) All chest radiographs which are first interpreted by an A or B
Reader will be submitted by NIOSH to a B Reader qualified as described
in Sec. 37.52. If there is agreement between the two interpretations,
as described in paragraph (b) of this section, the result will be
considered final and reported to MSHA for transmittal to the miner.
When agreement is lacking, NIOSH must obtain a third interpretation
from the panel of B Readers. If any two of the three interpretations
demonstrate agreement, the result must be considered the final
determination. If agreement is lacking among the three interpretations,
NIOSH will obtain independent classifications from two additional B
Readers selected from the panel, and the final determination will be
the median category derived from the total of five classifications.
(b) Two interpretations must be considered to be in agreement when
they are derived from complete classifications recorded using approved
paper or electronic versions of the Roentgenographic Interpretation
Form (Form CDC/NIOSH (M)2.8) and received by NIOSH, and both find
either stage A, B, or C complicated pneumoconiosis, or, for simple
pneumoconiosis, are both in the same major category or (with one
exception noted below) are within one minor category (ILO
Classification 12-point scale) of each other. In the last situation,
the higher of the two interpretations must be reported. The only
exception to the one minor category principle is a reading sequence of
\0/1\, \1/0\, or \1/0\, \0/1\, which is not considered agreement.
0
22. Revise newly designated Sec. 37.54 to read as follows:
Sec. 37.54 Notification of abnormal radiographic findings.
(a) Findings of, or findings suggesting, abnormality of cardiac
shape or size, tuberculosis, lung cancer, or any other significant
abnormal findings other than pneumoconiosis must be communicated by the
first physician to interpret the radiograph to the miner indicated on
the Miner Identification Document or to the miner's designated
physician. A notice
[[Page 56735]]
of the communication must be submitted to NIOSH. When significant
abnormal findings are reported, NIOSH will also notify the miner to
contact his or her physician.
(b) In addition, when NIOSH has more than one radiograph of a miner
in its files and the most recent examination was found by the first
physician to interpret the radiograph or subsequently by NIOSH B
Readers to show an abnormality of cardiac shape or size, tuberculosis,
cancer, complicated pneumoconiosis, and any other significant abnormal
findings, NIOSH will arrange for a licensed physician to compare the
most recent image and interpretation to older images and NIOSH will
inform the miner of any significant changes or progression of disease
or other findings.
(c) All final findings regarding pneumoconiosis will be sent to the
miner by MSHA in accordance with section 203 of the Act (see 30 CFR
part 90). Positive findings with regard to pneumoconiosis will be
reported to the miner or to the miner's designated physician by NIOSH.
(d) NIOSH will make every reasonable effort to process the findings
described in paragraph (c) of this section within 60 days of receipt of
the information described in Sec. 37.60 in a complete and acceptable
form. The information forwarded to MSHA will be in a form intended to
facilitate prompt dispatch of the findings to the miner. The results of
an examination made of a miner may not be processed by NIOSH if the
examination was made within 6 months of the date of a previous
acceptable examination.
0
23. Amend Sec. 37.60 by revising paragraphs (a) through (d) to read as
follows:
Sec. 37.60 Submitting required chest radiographs and miner
identification documents.
(a) Each chest radiograph required to be made under this subpart,
together with the completed Roentgenographic Interpretation Form and
the completed Miner Identification Document, must be submitted together
for each miner to NIOSH within 14 calendar days after the radiographic
examination is given and become the property of NIOSH.
(1) When the radiograph is digital, the image file for each
radiograph, together with either hard copy or electronic versions of
the completed Roentgenographic Interpretation Form and the completed
Miner Identification Document, must be submitted to NIOSH using the
software and format specified by NIOSH either using portable electronic
media, or a secure electronic file transfer within 14 calendar days
after the radiographic examination. NIOSH will notify the submitting
facility when it has received the image files and forms from the
examination. After this notification, the facility will permanently
delete, or if this is not technologically feasible for the imaging
system used, render permanently inaccessible all files and forms from
its electronic and physical files.
(2) [Reserved]
(b) If NIOSH deems any submission under paragraph (a) of this
section inadequate, it will notify the operator of the deficiency. The
operator must promptly make appropriate arrangements for the necessary
reexamination.
(c) Failure to comply with paragraph (a) or (b) of this section
will be cause to revoke approval of a plan or any other approval as may
be appropriate. An approval that has been revoked may be reinstated at
the discretion of NIOSH after it receives satisfactory assurances and
evidence that all deficiencies have been corrected and that effective
controls have been instituted to prevent a recurrence.
(d) Chest radiographs and other required documents must be
submitted only for miners.
* * * * *
0
24. Revise Sec. 37.70 to read as follows:
Sec. 37.70 Review of interpretations.
(a) Any miner who believes the interpretation for pneumoconiosis
reported to him or her by MSHA is in error may file a written request
with NIOSH that his or her radiograph be reevaluated. If the
interpretation was based on agreement between an A Reader and a B
Reader, NIOSH will obtain one or more additional interpretations by B
Readers as necessary to obtain agreement in accord with Sec. 37.53,
and MSHA must report the results to the miner together with
notification from MSHA of any rights which may accrue to the miner in
accordance with Sec. 37.7. If the reported interpretation was based on
agreement between two (or more) B Readers, the reading will be accepted
as conclusive and the miner must be so informed by MSHA.
(b) Any operator who is directed by MSHA to transfer a miner to a
less dusty atmosphere based on the most recent examination made
subsequent to August 1, 1978, may file a written request with NIOSH to
review its findings. The standards set forth in paragraph (a) of this
section apply and the operator and miner will be notified by MSHA
whether the miner is entitled to the option to transfer.
0
25. Revise Sec. 37.80 to read as follows:
Sec. 37.80 Availability of records for radiographs.
(a) Medical information and radiographs on miners will be released
by NIOSH only with the written consent from the miner, or if the miner
is deceased, written consent from the miner's widow or widower, next of
kin, or legal representative.
(b) To the extent authorized, radiographs will be made available
for examination only at NIOSH.
0
26. Amend Sec. 37.201 by revising paragraph (d) to read as follows:
Sec. 37.201 Definitions.
(d) NIOSH means the National Institute for Occupational Safety and
Health, United States Public Health Service, Department of Health and
Human Services, Post Office Box 4258, Morgantown, WV 26504.
0
27. Amend Sec. 37.202 by revising paragraphs (a)(2) and (b) to read as
follows:
Sec. 37.202 Payment for autopsy.
(a) * * *
(2) Submits the findings and other materials to NIOSH in accordance
with this subpart within 180 calendar days after having performed the
autopsy; and
* * * * *
(b) The Secretary will pay to any pathologist entitled to payment
under paragraph (a) of this section and additional $10 if the
pathologist can obtain and submits a good quality copy or original of a
chest radiograph (posteroanterior view) made of the subject of the
autopsy within 5 years prior to his death together with a copy of any
interpretation made.
0
28. Amend Sec. 37.204 by revising the introductory text and paragraph
(b), and removing Figure 1, to read as follows:
Sec. 37.204 Procedure for obtaining payment.
Every claim for payment under this subpart must be submitted to
NIOSH and must include:
* * * * *
(b) Completed PHS Consent, Release and History form (Form CDC/NIOSH
(M)2.6). This form may be completed with the assistance of the
pathologist, attending physician, family physician, or any other
responsible person who can provide reliable information.
* * * * *
Dated: August 28, 2012.
Kathleen Sebelius,
Secretary, Department of Health and Human Services.
[FR Doc. 2012-22253 Filed 9-12-12; 8:45 am]
BILLING CODE 4150-18-P