[Federal Register Volume 82, Number 137 (Wednesday, July 19, 2017)]
[Notices]
[Pages 33081-33099]
From the Federal Register Online via the Government Publishing Office [www.gpo.gov]
[FR Doc No: 2017-15130]
=======================================================================
-----------------------------------------------------------------------
DEPARTMENT OF ENERGY
Office of Energy Efficiency and Renewable Energy
[Case No. CR-007]
Notice of Petition for Waiver of ITW Food Equipment Group, LLC
From the Department of Energy Commercial Refrigeration Equipment Test
Procedures and Grant of Interim Waiver
AGENCY: Office of Energy Efficiency and Renewable Energy, Department of
Energy.
ACTION: Notice of petition for waiver and grant of interim waiver, and
request for public comment.
-----------------------------------------------------------------------
SUMMARY: This notice announces receipt of and publishes a petition for
waiver from ITW Food Equipment Group, LLC (ITW) seeking an exemption
from specified portions of the U.S. Department of Energy (DOE) test
procedure for determining the energy consumption of commercial
refrigeration equipment under the regulations for basic models of their
Innopod temperature controlled grocery and general merchandise system
(Innopod). ITW requests modifications, as specified in its petition for
waiver, to the existing DOE test procedure, which references Air-
Conditioning, and Refrigeration Institute (ARI) Standard 1200-2006 and
Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Standard
1200 (I-P)-2010 that further references American National Standards
Institute/American Society of Heating, Refrigerating and Air-
Conditioning Engineers (ANSI/ASHRAE) Standard 72. ITW submitted to DOE
an alternate test procedure that allows for testing of specified
Innopod basic models. This notice also announces that DOE has granted
ITW an interim waiver from the DOE commercial refrigeration equipment
test procedures for the specified commercial refrigeration equipment
basic models, subject to use of the alternative test procedure as set
forth in this notice. DOE solicits comments, data, and information
concerning ITW's petition and its suggested alternate test procedure.
DATES: DOE will accept comments, data, and information with regard to
the ITW petition until August 18, 2017.
ADDRESSES: You may submit comments, identified by Case No. CR-007, by
any of the following methods:
Federal eRulemaking Portal: http://www.regulations.gov.
Follow the instructions for submitting comments.
Email: [email protected]. Include the case
number [Case No. CR-007] in the subject line of the message. Submit
electronic comments in WordPerfect, Microsoft Word, PDF, or ASCII file
format, and avoid the use of special characters or any form of
encryption.
Postal Mail: Mr. Bryan Berringer, U.S. Department of
Energy, Building Technologies Office, Mailstop EE-5B, Petition for
Waiver Case No. CR-007, 1000 Independence Avenue SW., Washington, DC
20585-0121. Telephone: (202) 586-0371. If possible, please submit all
items on a compact disc (CD), in which case it is not necessary to
include printed copies.
Hand Delivery/Courier: Appliance and Equipment Standards
Program, U.S. Department of Energy, Building Technologies Office, 950
L'Enfant Plaza SW., 6th Floor, Washington, DC, 20024. Telephone: (202)
586-6636. If possible, please submit all items on a CD, in which case
it is not necessary to include printed copies.
Docket: The docket, which includes Federal Register notices,
comments, and other supporting documents/materials, is available for
review at http://www.regulations.gov. All documents in the docket are
listed in the http://www.regulations.gov index. However, some documents
listed in the index, such as those containing information that is
exempt from public disclosure, may not be publicly available.
FOR FURTHER INFORMATION CONTACT: Mr. Bryan Berringer, U.S. Department
of Energy, Building Technologies Office, Mailstop EE-5B, 1000
Independence Avenue SW., Washington, DC 20585-0121. Telephone: (202)
586-0371. Email: [email protected].
SUPPLEMENTARY INFORMATION:
I. Background and Authority
Title III, Part C \1\ of the Energy Policy and Conservation Act of
1975 (EPCA), Public Law 94-163 (42 U.S.C. 6311-6316, as codified)
established the Energy Conservation Program for Certain Industrial
Equipment, which includes commercial refrigeration equipment.\2\ Part C
includes definitions, test procedures, labeling provisions, energy
conservation standards, and the authority to require information and
reports from manufacturers. Further, Part C authorizes the Secretary of
Energy to prescribe test procedures that are reasonably designed to
produce results that measure energy efficiency, energy use, or
estimated operating costs during a representative average-use cycle,
and that are not unduly burdensome to conduct. (42 U.S.C. 6314(a)(2))
The test procedure for commercial refrigeration equipment is contained
in Title 10 of the CFR part 431, subpart C, appendix B, ``Amended
Uniform Test Method for the Measurement of Energy Consumption of
Commercial Refrigerators, Freezers, and Refrigerator-Freezers.''
---------------------------------------------------------------------------
\1\ For editorial reasons, upon codification in the U.S. Code,
Part C was redesignated as Part A-1.
\2\ All references to EPCA in this document refer to the statute
as amended through the Energy Efficiency Improvement Act of 2015
(EEIA), Public Law 114-11 (April 30, 2015).
---------------------------------------------------------------------------
DOE's regulations set forth at 10 CFR 431.401 contain provisions
that allow a person to seek a waiver from the test procedure
requirements for a particular basic model of a type of covered
equipment when the petitioner's basic model for which the petition for
waiver was submitted contains one or more design characteristics that
either (1) prevent testing according to the prescribed test procedures;
or (2) cause the prescribed test procedures to evaluate the basic model
in a manner so unrepresentative of its true energy consumption as to
provide materially inaccurate comparative data. 10 CFR 431.401(a)(1). A
petitioner must include in its petition any alternate test procedures
known to the petitioner to evaluate the basic model in a manner
representative of its energy consumption. 10 CFR 431.401(b)(1)(iii).
DOE may grant a waiver subject to conditions, including adherence
to alternate test procedures. 10 CFR 431.401(f)(2). As soon as
practicable after the granting of any waiver, DOE will publish in the
Federal Register a notice of proposed rulemaking to amend its
regulations so as to eliminate any need for the continuation of such
waiver. As soon thereafter as practicable, DOE will publish in the
Federal Register a final rule. 10 CFR 431.401(l).
The waiver process also allows DOE to grant an interim waiver if it
appears likely that the petition for waiver will be granted and/or if
DOE determines that it would be desirable for public policy reasons to
grant immediate relief pending a determination on the petition
[[Page 33082]]
for waiver. 10 CFR 431.401(e)(2). Within one year of issuance of an
interim waiver, DOE will either: (i) Publish in the Federal Register a
determination on the petition for waiver; or (ii) publish in the
Federal Register a new or amended test procedure that addresses the
issues presented in the waiver. 10 CFR 431.401(h)(1). When DOE amends
the test procedure to address the issues presented in a waiver, the
waiver will automatically terminate on the date on which use of that
test procedure is required to demonstrate compliance. 10 CFR
431.401(h)(2).
II. ITW's Petition for Waiver of Test Procedure and Application for
Interim Waiver
On December 20, 2016, ITW submitted a petition for waiver and
interim waiver pursuant to 10 CFR 431.401 pertaining to DOE's test
procedure at 10 CFR part 431, subpart C, appendix B, for their Innopod
temperature controlled grocery and general merchandise system (Innopod)
basic models of commercial refrigeration equipment. ITW's initial
petition included twenty-two base model configurations. On May 3, 2017,
ITW provided DOE with the complete list of 200 basic models covered by
the twenty-two base model configurations. ITW petitioned for a waiver
and interim waiver from various DOE test procedure requirements.
DOE's current test procedure references Air-Conditioning, and
Refrigeration Institute (ARI) Standard 1200-2006 and Air-Conditioning,
Heating, and Refrigeration Institute (AHRI) Standard 1200 (I-P)-2010,
which further references American National Standards Institute/American
Society of Heating, Refrigerating and Air-Conditioning Engineers (ANSI/
ASHRAE) Standard 72 (incorporated by reference at 10 CFR 431.63 (c) and
(d)). ITW asserts that these current test procedures do not account for
the unique operating characteristics of the Innopod basic models.
Because the specific design of this product line contains one or more
design characteristics noted in the waiver request, including floating
suction temperatures for individual compartments, different typical
door-opening cycles, and a high-temperature ``ambient'' compartment,
ITW believes that its petition and combined application meets both
conditions of 10 CFR 431.401(a)(1) for granting waivers, on the grounds
that: (1) The petitioner's basic model contains one or more design
characteristics that prevent testing according to the prescribed test
procedures; and (2) The prescribed test procedures may evaluate the
basic model in a manner so unrepresentative of its true energy
consumption as to provide materially inaccurate comparative data. ITW
submitted to DOE an alternate test procedure that allows for testing of
its Innopod basic models.
ITW's Innopod basic models include multiple thermally separated,
temperature controlled compartments supplied with refrigerant from a
single condensing unit. ITW's petition proposes an alternate test using
an ``inverse refrigeration load'' test, various calculations to account
for refrigeration system and component energy consumption, and
adjustments to the door opening requirements based on typical use in
the field. ITW's proposed refrigeration system calculations rely on the
current calculations and assumptions used for testing remote condensing
commercial refrigeration equipment in accordance with the DOE test
procedure.
As previously noted, an interim waiver may be granted if it appears
likely that the petition for waiver will be granted, and/or if DOE
determines that it would be desirable for public policy reasons to
grant immediate relief pending a determination of the petition for
waiver. See 10 CFR 431.401(e)(2).
DOE understands that absent an interim waiver, the basic models
identified by ITW in its petition cannot be tested and rated for energy
consumption on a basis representative of their true energy consumption
characteristics. DOE has reviewed the alternate procedure suggested by
ITW and concludes that it will allow for the accurate measurement of
the energy use of these equipment, while alleviating the testing
problems associated with ITW's implementation of DOE's applicable
commercial refrigeration equipment test procedure for the specified
Innopod models. However, DOE has clarified how ITW should determine
basic models, as discussed in section III of this notice, and adjusted
certain aspects of the requested alternate test procedure regarding
ambient test conditions, referenced industry standards, and
calculations, as discussed in section IV of this notice. Thus, DOE has
determined that ITW's petition for waiver will likely be granted and
has decided that it is desirable for public policy reasons to grant ITW
immediate relief pending a determination on the petition for waiver.
III. Petition for Waiver and Interim Waiver Basic Models
ITW's initial petition for waiver and interim waiver, submitted on
December 20, 2016, included a list of twenty-two ``base model
configurations'' of its Innopod equipment. However, based on the
descriptions of the compartment configurations provided for each base
model configuration, DOE expects that the list does not provide each
basic model to which the waiver and interim waiver would apply.
Specifically, DOE noted that many of the base model configurations
include compartments that are convertible between the freezer and
refrigerator temperature operating ranges. With respect to multi-mode
operation, DOE has taken the position in the most recent commercial
refrigeration equipment test procedure final rule that self-contained
equipment or remote condensing equipment with thermostats capable of
operating at temperatures that span multiple equipment categories must
be certified and comply with DOE's regulations for each applicable
equipment category. 79 FR 22291 (April 21, 2014).
Additionally, DOE notes that its current regulations allow for the
use of alternative efficiency determination methods (AEDMs), which
allow manufacturers to simulate the energy use of untested basic models
once a manufacturer has a validated AEDM and could be used to simulate
results at other rating temperatures. 10 CFR 429.70.
Under DOE's definition of a basic model as ``equipment manufactured
by one manufacturer within a single equipment class, having the same
primary energy source, and that have essentially identical electrical,
physical, and functional characteristics that affect energy
consumption'' (10 CFR 431.62), the base model configurations in ITW's
initial petition would represent multiple basic models depending on the
set point of the convertible compartments. DOE requested that ITW
provide an updated list of basic models, consistent with DOE's
definition of basic model, that would be covered by the petition for
waiver and request for interim waiver. ITW provided DOE with the
updated list of basic model numbers on May 3, 2017.
ITW's petition also describes compartments that are convertible
between refrigerator and ambient temperature ranges. These compartments
would only be considered refrigerator compartments under DOE's
definitions (compartments capable of operating at or above
32[emsp14][deg]F
[[Page 33083]]
(2[deg]F)). Accordingly, these compartments would only be
tested and rated at the refrigerator compartment standardized
temperature (38[emsp14][deg]F).
IV. Summary of Grant of Interim Waiver
For the reasons stated in section II of this notice, DOE has
granted ITW's application for interim waiver from testing for its
specified commercial refrigeration equipment basic models, with minor
modifications to the proposed approach. The substance of the interim
waiver is summarized below.
ITW is required to test and rate the specified ITW commercial
refrigeration equipment Innopod basic models \3\ according to the
alternate test procedure as set forth in section V, ``Alternate Test
Procedure.'' DOE has revised ITW's proposed test approach to reflect
ambient test conditions that are consistent with those required in the
DOE test procedure. DOE has determined that the ambient condition
requirement would not prevent testing of the Innopod basic models.
Additionally, DOE has revised ITW's proposed alternate approach to
reference the current version of the AHRI 1200 standard referenced in
DOE's existing test procedure. Further, DOE has clarified certain
details of the necessary measurements and calculations in the granted
interim waiver.
---------------------------------------------------------------------------
\3\ 30-XX-X5-AAAAR, 30-XX-X5-AAARA, 30-XX-X5-AAARR, 30-XX-X5-
AAAFA, 30-XX-X5-AAAFR, 30-XX-X5-AARAA, 30-XX-X5-AARAR, 30-XX-X5-
AARRA, 30-XX-X5-AARRR, 30-XX-X5-AARFA, 30-XX-X5-AARFR, 30-XX-X5-
AAFAA, 30-XX-X5-AAFAR, 30-XX-X5-AAFRA, 30-XX-X5-AAFRR, 30-XX-X5-
AAFFA, 30-XX-X5-AAFFR, 30-XX-X5-ARAAA, 30-XX-X5-ARAAR, 30-XX-X5-
ARARA, 30-XX-X5-ARARR, 30-XX-X5-ARAFA, 30-XX-X5-ARAFR, 30-XX-X5-
ARRAA, 30-XX-X5-ARRAR, 30-XX-X5-ARRRA, 30-XX-X5-ARRRR, 30-XX-X5-
ARRFA, 30-XX-X5-ARRFR, 30-XX-X5-ARFAA, 30-XX-X5-ARFAR, 30-XX-X5-
ARFRA, 30-XX-X5-ARFRR, 30-XX-X5-ARFFA, 30-XX-X5-ARFFR, 30-XX-X5-
AFAAA, 30-XX-X5-AFAAR, 30-XX-X5-AFARA, 30-XX-X5-AFARR, 30-XX-X5-
AFAFA, 30-XX-X5-AFAFR, 30-XX-X5-AFRAA, 30-XX-X5-AFRAR, 30-XX-X5-
AFRRA, 30-XX-X5-AFRRR, 30-XX-X5-AFRFA, 30-XX-X5-AFRFR, 30-XX-X5-
AFFAA, 30-XX-X5-AFFAR, 30-XX-X5-AFFRA, 30-XX-X5-AFFRR, 30-XX-X5-
RAAAA, 30-XX-X5-RAAAR, 30-XX-X5-RAARA, 30-XX-X5-RAARR, 30-XX-X5-
RAAFA, 30-XX-X5-RAAFR, 30-XX-X5-RARAA, 30-XX-X5-RARAR, 30-XX-X5-
RARRA, 30-XX-X5-RARRR, 30-XX-X5-RARFA, 30-XX-X5-RARFR, 30-XX-X5-
RAFAA, 30-XX-X5-RAFAR, 30-XX-X5-RAFRA, 30-XX-X5-RAFRR, 30-XX-X5-
RAFFA, 30-XX-X5-RAFFR, 30-XX-X5-RRAAA, 30-XX-X5-RRAAR, 30-XX-X5-
RRARA, 30-XX-X5-RRARR, 30-XX-X5-RRAFA, 30-XX-X5-RRAFR, 30-XX-X5-
RRRAA, 30-XX-X5-RRRAR, 30-XX-X5-RRRRA, 30-XX-X5-RRRFA, 30-XX-X5-
RRFAA, 30-XX-X5-RRFAR, 30-XX-X5-RRFRA, 30-XX-X5-RRFFA, 30-XX-X5-
RFAAA, 30-XX-X5-RFAAR, 30-XX-X5-RFARA, 30-XX-X5-RFARR, 30-XX-X5-
RFAFA, 30-XX-X5-RFAFR, 30-XX-X5-RFRAA, 30-XX-X5-RFRAR, 30-XX-X5-
RFRRA, 30-XX-X5-RFRFA, 30-XX-X5-RFFAA, 30-XX-X5-RFFAR, 30-XX-X5-
RFFRA, 30-XX-X5-FAAAA, 30-XX-X5-FAAAR, 30-XX-X5-FAARA, 30-XX-X5-
FAARR, 30-XX-X5-FAAFA, 30-XX-X5-FAAFR, 30-XX-X5-FARAA, 30-XX-X5-
FARAR, 30-XX-X5-FARRA, 30-XX-X5-FARRR, 30-XX-X5-FARFA, 30-XX-X5-
FARFR, 30-XX-X5-FAFAA, 30-XX-X5-FAFAR, 30-XX-X5-FAFRA, 30-XX-X5-
FAFRR, 30-XX-X5-FRAAA, 30-XX-X5-FRAAR, 30-XX-X5-FRARA, 30-XX-X5-
FRARR, 30-XX-X5-FRAFA, 30-XX-X5-FRAFR, 30-XX-X5-FRRAA, 30-XX-X5-
FRRAR, 30-XX-X5-FRRRA, 30-XX-X5-FRRFA, 30-XX-X5-FRFAA, 30-XX-X5-
FRFAR, 30-XX-X5-FRFRA, 30-XX-X5-FFAAA, 30-XX-X5-FFAAR, 30-XX-X5-
FFARA, 30-XX-X5-FFARR, 30-XX-X5-FFRAA, 30-XX-X5-FFRAR, 30-XX-X5-
FFRRA, 30-XX-X4A-AAAR, 30-XX-X4A-AARA, 30-XX-X4A–AARR, 30-XX-
X4A-ARAA, 30-XX-X4A-ARAR, 30-XX-X4A-ARRA, 30-XX-X4A-ARRR, 30-XX-X4A-
AFAA, 30-XX-X4A-AFAR, 30-XX-X4A-AFRA, 30-XX-X4A-AFRR, 30-XX-X4A-
RAAA, 30-XX-X4A-RAAR, 30-XX-X4A-RARA, 30-XX-X4A-RARR, 30-XX-X4A-
RRAA, 30-XX-X4A-RRAR, 30-XX-X4A-RRRA, 30-XX-X4A-RFAA, 30-XX-X4A-
RFAR, 30-XX-X4A-RFRA, 30-XX-X4A-FAAA, 30-XX-X4A-FAAR, 30-XX-X4A-
FARA, 30-XX-X4A-FARR, 30-XX-X4A-FRAA, 30-XX-X4A-FRAR, 30-XX-X4A-
FRRA, 30-XX-X4A-FFAA, 30-XX-X4A-FFAR, 30-XX-X4A-FFRA, 30-XX-X4B-
AAAR, 30-XX-X4B-AARA, 30-XX-X4B-AARR, 30-XX-X4B-AAFA, 30-XX-X4B-
AAFR, 30-XX-X4B-ARAA, 30-XX-X4B-ARAR, 30-XX-X4B-ARRA, 30-XX-X4B-
ARRR, 30-XX-X4B-ARFA, 30-XX-X4B-ARFR, 30-XX-X4B-AFAA, 30-XX-X4B-
AFAR, 30-XX-X4B-AFRA, 30-XX-X4B-AFRR, 30-XX-X4B-AFFA, 30-XX-X4B-
AFFR, 30-XX-X4B-RAAA, 30-XX-X4B-RAAR, 30-XX-X4B-RARA, 30-XX-X4B-
RARR, 30-XX-X4B-RAFA, 30-XX-X4B-RAFR, 30-XX-X4B-RRAA, 30-XX-X4B-
RRAR, 30-XX-X4B-RRRA, 30-XX-X4B-RRFA, 30-XX-X4B-RFAA, 30-XX-X4B-
RFAR, 30-XX-X4B-RFRA, 30-XX-X4B-RFFA, 30-XX-XX-3-AAR, 30-XX-XX-3-30-
XX-XX-3-ARA, 30-XX-XX-3-ARR, 30-XX-XX-3-RAA, 30-XX-XX-3-RAR, and 30-
XX-XX-3-RRA.
---------------------------------------------------------------------------
In addition, DOE is requiring that ITW test compartments in all
relevant equipment configurations, as required by the current test
procedure. Any compartments that are convertible between the
refrigerator and freezer operating temperature ranges must be tested
and rated under both test settings; however, the compartments in the
ITW equipment that are convertible between ambient and refrigerator
temperature ranges must be tested only at the refrigerator standardized
compartment temperature of 38 [deg]F, as described in section III of
this notice.
ITW must make representations about the energy use of these basic
models for compliance, marketing, or other purposes only to the extent
that such equipment have been tested in accordance with the provisions
set forth in the alternate test procedure and such representations
fairly disclose the results of such testing in accordance with 10 CFR
part 429, subpart B.
DOE makes decisions on waivers and interim waivers for only those
basic models specifically set out in the petition, not future models
that may be manufactured by the petitioner. ITW may request that DOE
extend the scope of a waiver or an interim waiver to include additional
basic models employing the same technology as the basic models set
forth in the original petition consistent with 10 CFR 431.401(g). In
addition, DOE notes that granting of an interim waiver or waiver does
not release a petitioner from the certification requirements set forth
at 10 CFR part 429. See also 10 CFR 431.401(a) and (i).
The interim waiver shall remain in effect consistent with 10 CFR
431.401(h). Furthermore, this interim waiver is conditioned upon the
presumed validity of statements, representations, and documents
provided by the petitioner. DOE may rescind or modify a waiver or
interim waiver at any time upon a determination that the factual basis
underlying the petition for waiver or interim waiver is incorrect, or
upon a determination that the results from the alternate test procedure
are unrepresentative of the basic model's true energy consumption
characteristics. See 10 CFR 431.401(k).
V. Alternate Test Procedure
EPCA requires that manufacturers use DOE test procedures when
making representations about the energy consumption and energy
consumption costs of equipment covered by the statute. (42 U.S.C.
6293(c); 6314(d)) Consistent representations about the energy
efficiency of covered equipment are important for consumers evaluating
equipment when making purchasing decisions and for manufacturers to
demonstrate compliance with applicable DOE energy conservation
standards. Pursuant to its regulations applicable to waivers and
interim waivers from applicable test procedures at 10 CFR 431.401, and
after considering public comments on the petition, DOE will announce
its decision as to an alternate test procedure for ITW in a subsequent
Decision and Order.
During the period of the interim waiver granted in this notice, ITW
shall test the basic models listed in section IV according to the test
procedure for commercial refrigeration equipment prescribed by DOE at
10 CFR part 431, subpart C, appendix B, with some of the modifications
to the existing DOE test requirements as specified in ITW's petition.
However, DOE is requiring that ITW test its Innopod basic models
according to the ambient test conditions as outlined in AHRI Standard
1200 (I-P)-2010 section 4.1.2, which requires a wet-bulb test room
temperature of 64.4 [deg]F 1.8 [deg]F, rather than the
conditions
[[Page 33084]]
requested in the petition for waiver, which instead specify a test room
dew point. Additionally, DOE has revised ITW's proposed alternate
approach to reference the current version of the AHRI 1200 standard
referenced in DOE's existing test procedure, AHRI Standard 1200 (I-P)-
2010. DOE has also clarified certain instructions, calculations, and
measurements necessary to conduct the alternate test. Accordingly, DOE
grants an interim waiver to ITW, but with modifications to ITW's
requested approach. The applicable method of test for the specified ITW
basic models is the test procedure for commercial refrigeration
equipment prescribed by DOE at 10 CFR 431, subpart C, appendix B, with
the following modifications:
For the purpose of testing and rating, the Ambient (75 [deg]F)
compartment is treated as a Medium (Refrigerator at 75 [deg]F)
compartment. All volume and energy consumption calculations will be
included within the Medium (Refrigerator 38 [deg]F) category and summed
with other Medium (Refrigerator 38 [deg]F) compartment calculation(s).
Compartments that are convertible between ambient and refrigerator
temperature ranges shall be tested at the refrigerator temperature (38
[deg]F). Compartments that are convertible between refrigerator and
freezer (0 [deg]F) temperature ranges shall be tested at both
temperatures.
BILLING CODE 6450-01-P
[[Page 33085]]
[GRAPHIC] [TIFF OMITTED] TN19JY17.004
[[Page 33086]]
[GRAPHIC] [TIFF OMITTED] TN19JY17.005
BILLING CODE 6450-01-C
VI. Summary and Request for Comments
Through this notice, DOE announces receipt of ITW's petition for
waiver from the DOE test procedure for certain basic models of ITW
commercial refrigeration equipment, and announces DOE's decision to
grant ITW an interim waiver from the test procedure for the specified
basic models of commercial refrigeration equipment. DOE is publishing
ITW's petition for waiver in redacted form, pursuant to 10 CFR
431.401(b)(1)(iv). The petition contains confidential information. The
petition includes a suggested alternate test procedure to determine the
energy consumption of specific basic models of commercial refrigeration
equipment. DOE may consider including this alternate procedure in a
subsequent Decision and Order based on comments from interested
parties. However, DOE has tentatively determined that the alternate
procedure proposed by ITW is not entirely acceptable and has provided a
modified alternate test procedure as a part of its grant of an interim
waiver. DOE will consider public comments on the petition in issuing
its Decision and Order.
DOE solicits comments from interested parties on all aspects of the
petition, including the suggested alternate test procedure and
calculation methodology. Pursuant to 10 CFR 431.401(d), any person
submitting written comments to DOE must also send a copy of such
comments to the petitioner. The contact information for the
petitioner's representative is Ms. Mary Dane, Agency Approval Engineer,
ITW Food Equipment Group, LLC, North American Refrigeration, 4401 Blue
Mound Rd., Fort Worth, TX 76106. All comment submissions must include
the agency name and Case No. CR-007 for this proceeding. Submit
electronic comments in WordPerfect, Microsoft Word, Portable Document
Format (PDF), or text (American Standard Code for Information
Interchange (ASCII)) file format and avoid the use of special
characters or any form of encryption. Wherever possible, include the
electronic signature of the author. DOE does not accept telefacsimiles
(faxes).
Pursuant to 10 CFR 1004.11, any person submitting information that
he or she believes to be confidential and exempt by law from public
disclosure should submit two copies to DOE: One copy of the document
marked ``confidential'' with all of the information believed to be
confidential included, and one copy of the document marked ``non-
confidential'' with all of the information believed to be confidential
deleted. DOE will make its own determination about the confidential
status of the information and treat it according to its determination.
Issued in Washington, DC, on July 11, 2017.
Kathleen B. Hogan,
Deputy Assistant Secretary for Energy Efficiency, Energy Efficiency and
Renewable Energy.
BILLING CODE 6450-01-P
[[Page 33087]]
[GRAPHIC] [TIFF OMITTED] TN19JY17.006
[[Page 33088]]
[GRAPHIC] [TIFF OMITTED] TN19JY17.007
[[Page 33089]]
[GRAPHIC] [TIFF OMITTED] TN19JY17.008
[[Page 33090]]
[GRAPHIC] [TIFF OMITTED] TN19JY17.009
[[Page 33091]]
[GRAPHIC] [TIFF OMITTED] TN19JY17.010
[[Page 33092]]
[GRAPHIC] [TIFF OMITTED] TN19JY17.011
[[Page 33093]]
[GRAPHIC] [TIFF OMITTED] TN19JY17.012
[[Page 33094]]
[GRAPHIC] [TIFF OMITTED] TN19JY17.013
[[Page 33095]]
[GRAPHIC] [TIFF OMITTED] TN19JY17.014
[[Page 33096]]
[GRAPHIC] [TIFF OMITTED] TN19JY17.015
[[Page 33097]]
[GRAPHIC] [TIFF OMITTED] TN19JY17.016
[[Page 33098]]
[GRAPHIC] [TIFF OMITTED] TN19JY17.017
[[Page 33099]]
[GRAPHIC] [TIFF OMITTED] TN19JY17.018
[FR Doc. 2017-15130 Filed 7-18-17; 8:45 am]
BILLING CODE 6450-01-C