NUCLEAR REGULATORY COMMISSION
[Docket No. 50-244]
Rochester Gas and Electric Corporation; R.E. Ginna Nuclear Power
Plant; Environmental Assessment and Finding of No Significant Impact
The U.S. Nuclear Regulatory Commission (the Commission) is
considering issuance of an exemption from certain requirements of its
regulations for Facility Operating License No. DRP-18 issued to
Rochester Gas and Electric Corporation (the licensee), for operation of
the R.E. Ginna Nuclear Power Plant located in Wayne County, New York.
Environmental Assessment
Identification of Proposed Action
The proposed action would exempt Rochester Gas and Electric
Corporation from the requirements of 10 CFR 70.24, which requires a
monitoring system that will energize clear audible alarms if accidental
criticality occurs in each area in which special nuclear material is
handled, used, or stored. The proposed action would also exempt the
licensee from the requirements to maintain emergency procedures for
each area in which this licensed special nuclear material is handled,
used, or stored to ensure that all personnel withdraw to an area of
safety upon the sounding of the alarm, to familiarize personnel with
the evacuation plan, and to designate responsible individuals for
determining the cause of the alarm, and to place radiation survey
instruments in accessible locations for use in such an emergency.
The proposed action is in accordance with the licensee's
application for exemption dated June 5, 1997.
The Need for the Proposed Action
The purpose of 10 CFR 70.24 is to ensure that if a criticality were
to occur during the handling of special nuclear material, personnel
would be alerted to that fact and would take appropriate action. At a
commercial nuclear power plant the inadvertent criticality with which
10 CFR 70.24 is concerned could occur during fuel handling operations.
The special nuclear material that could be assembled into a critical
mass at a commercial nuclear power plant is in the form of nuclear
fuel; the quantity of other forms of special nuclear material that is
stored on site is small enough to preclude achieving a critical mass.
Because the fuel is not enriched beyond 5.0 weight percent Uranium-235
and because commercial nuclear plant licensees have procedures and
design features that prevent inadvertent criticality, the staff has
determined that an inadvertent criticality would not likely occur due
to the handling of special nuclear material at a commercial power
reactor. The requirements of 10 CFR 70.24, therefore, are not necessary
to ensure the safety of personnel during the handling of special
nuclear materials at commercial power reactors.
Environmental Impacts of the Proposed Action
The Commission has completed its evaluation of the proposed action
and concludes that there is no significant environmental impact if the
exemption is granted. Inadvertent or accidental criticality will be
precluded through compliance with the R.E. Ginna Nuclear Plant
Technical Specifications, the design of the fuel storage racks
providing geometric spacing of fuel assemblies in their storage
locations, and administrative controls imposed on fuel handling
procedures. Technical Specifications requirements specify reactivity
limits for the fuel storage racks and minimum spacing between the fuel
assemblies in the storage racks.
Appendix A of 10 CFR Part 50, ``General Design Criteria for Nuclear
Power Plants,'' Criterion 62, requires the criticality in the fuel
storage and handling system shall be prevented by physical systems or
processes, preferably by use of geometrically-safe configurations. This
is met at Ginna, as identified in the Technical Specifications and the
Updated Final Safety Analysis Report (UFSAR). Ginna Technical
Specifications Section 4.3, Fuel Storage, states that the spent fuel
storage racks are designed with Keff 0.95 if
fully flooded with unborated water: and new fuel racks are designed
with Keff 0.95 if fully flooded with unborated
water; and Keff 0.98 if moderated by aqueous
foam. UFSAR Section 9.1.1, New Fuel Storage, states that the spacing of
new fuel assemblies ensures a Keff less than 0.95 for the accidental
full water density flooding scenario and less than 0.98 for the
accidental low water density (optimum moderation) flooding scenario.
The proposed exemption would not result in any significant
radiological impacts. The proposed exemption would not affect
radiological plant effluent nor cause any significant occupational
exposures since the Technical Specifications, design controls
(including geometric spacing of fuel assembly storage spaces) and
administrative controls preclude inadvertent criticality. The amount of
radioactive waste would not be changed by the proposed exemption.
The proposed exemption does not result in any significant
nonradiological environmental impacts. The proposed exemption involves
features located entirely within the restricted area as defined in 10
CFR Part 20. It does not affect nonradiological plant effluents and has
no other environmental impact. Accordingly, the Commission concludes
that there are no significant nonradiological environmental impacts
associated with the proposed action.
Alternatives to the Proposed Action
Since the Commission has concluded that there is no measurable
environmental impact associated with the proposed action, any
alternatives with equal or greater environmental
[[Page 38591]]
impact need not be evaluated. As an alternative to the proposed
exemption, the staff considered denial of the requested exemption.
Denial of the request would result in no change in current
environmental impacts. The environmental impacts of the proposed action
and the alternative action are similar.
Alternative Use of Resources
This action does not involve the use of any resources not
previously considered in the ``Final Environmental Statement For the
R.E. Ginna Nuclear Power Plant dated December 1973.
Agencies and Persons Consulted
In accordance with its stated policy, on June 10, 1997, the staff
consulted with Mr. Jack Spath of the New York State Energy Research and
Development Authority, regarding the environmental impact of the
proposed action. The State official had no comments.
Finding of No Significant Impact
Based upon the environmental assessment, the Commission concludes
that the proposed action will not have a significant effect on the
quality of the human environment, Accordingly, the Commission has
determined not to prepare an environmental impact statement for the
proposed action.
For further details with respect to the proposed action, see the
licensee's letter dated June 5, 1997, which is available for public
inspection at the Commission's Public Document Room, which is located
at The Gelman Building, 2120 L Street, NW., Washington, D.C., and at
the local public document room located at the Rochester Public Library,
115 South Avenue, Rochester, New York.
Dated at Rockville, Maryland, this ninth day of July 1997.
For the Nuclear Regulatory Commission.