[Federal Register Volume 80, Number 76 (Tuesday, April 21, 2015)]
[Rules and Regulations]
[Page 22116]
From the Federal Register Online via the Government Publishing Office [www.gpo.gov]
[FR Doc No: 2015-09202]



[[Page 22116]]

-----------------------------------------------------------------------

ENVIRONMENTAL PROTECTION AGENCY

40 CFR Part 63


National Emission Standards for Hazardous Air Pollutants for 
Source Categories

CFR Correction

    In Title 40 of the Code of Federal Regulations, Part 63, Sec. Sec.  
63.1 to 63.599, revised as of July 1, 2014, on page 478, in Sec.  
63.343, paragraph (c)(5)(ii) is correctly revised to read as follows:


Sec.  63.343  Compliance provisions. [Corrected]

* * * * *
    (c) * * *
    (5) * * *
    (ii) On and after the date on which the initial performance test is 
required to be completed under Sec.  63.7, the owner or operator of an 
affected source shall monitor the surface tension of the electroplating 
or anodizing bath. Operation of the affected source at a surface 
tension greater than the value established during the performance test, 
or greater than 40 dynes/cm, as measured by a stalagmometer, or 33 
dynes/cm, as measured by a tensiometer, if the owner or operator is 
using this value in accordance with paragraph (c)(5)(i) of this 
section, shall constitute noncompliance with the standards. The surface 
tension shall be monitored according to the following schedule:
* * * * *
[FR Doc. 2015-09202 Filed 4-20-15; 8:45 am]